Extron electronic manual FrontPanelOperation,co t’d, USP 507 Menu System, Overview of menus

Page 24

FrontPanelOperation,co t’d

The USP 507 Menu System

The USP 507 can be configured using the menu system, via the Extron Simple Instruction Set (SIS) of commands through an RS-232 or LAN connected PC, or via the Extron software program, SPPCP.

NFor SIS commands and SPPCP configuration methods see chapters 4 and 5.

There are seven front panel configuration menus: User Presets, Input Configuration, Output Configuration, Image Capture/Recall, Advanced Configuration, and View Comm Settings. A hidden menu (Edit Comm Settings) is also accessible. If an optional Scan Converter board is installed, an eighth menu (scan converter menu) is available.

User

Menu

Input

Menu

Output

Menu

Image

Presets

 

Configuration

 

Configuration

 

Capture/Recall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu

 

 

 

Menu

 

 

 

Menu

 

 

Advanced

View Comm

Menu

Scan

Exit Menu

Configuration

 

Settings

 

Converter

 

Press NEXT

 

 

 

 

 

only where optional Scan

 

 

 

 

 

 

 

 

Converter card is installed

 

 

 

Overview of menus

User Presets

This menu allows the user to save the current image settings to a preset number (1-16 for each input), and recall any saved preset as the current image settings.

Input Configuration

This menu allows configuration of the following settings for any selected input: Input type, film detection, vertical and horizontal start points, pixel phase, the number of total and active pixels and the number of active lines.

Output Configuration

This menu allows configuration of the following settings for the active output: resolution and refresh rate (see page 3-8), output type, and sync polarity.

Image Capture/Recall

This menu allows any one of up to 16 stored images to be recalled to the display, as either a background to an active video signal, or in front of the active signal. It also allows the user to store the current displayed image on the device for later recall.

Advanced Configuration

This menu allows advanced configuration of the following USP 507 settings: auto image, input EDID, auto memories, RGB delay, switch effect, test pattern, MTP pre-peaking, internal temp (view only), and resetting to factory defaults.

View Comm Settings

This menu allows the user to view the following serial and IP settings for the unit: serial port baud rate, MAC address, DHCP (Dynamic Host Configuration Protocol) setting, IP address, subnet mask address, and gateway address.

NThese settings can not be edited from within this menu. See next section.

Edit Comm Settings (hidden)

To display and enter this menu, press and hold the Detail and Color/Tint buttons simultaneously and then press Next. The hidden menu appears.

This menu allows the user to edit the following serial and IP settings:

serial port baud rate, DHCP mode, IP address, subnet mask, and gateway address.

Scan Converter Configuration

This menu, displayed only when the optional scan-converter board is installed, allows the user to configure the settings for scan-converted outputs.

Exit Menu

At this menu pressing Next exits the menu system and returns to the default cycle.

3-4 USP 507 • Front Panel Operation

Image 24
Contents Universal Signal Processor USPPrecautions Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschFCC Class a Notice Table of Contents Table of Contents, cont’d Installing and Starting the Signal Processing USP 507 Table of Contents IiiIv USP 507 Table of Contents One Introduction About this ManualAbout the USP USP 507 IntroductionDefinitions Features Introduction, cont’dUSP 507 Introduction Two Installationstallation, cont’d UL/Safety RequirementsImportant safety instructions USP 507 InstallationTabletop placement Mounting the USPUL guidelines for rack mounted devices Rack mountingInstallation, cont’d Rear Panel Features and ConnectionsPower and video input connections Output, user interface, and control connections Installation and cabling Powering Up Resetting the Unit with the Reset ButtonDefault display cycle USP 507 Reset Mode Summary Mode Activation Result Purpose/NotesThree Front Panel Operation Front Panel OverviewSpecial function buttons These four buttons are Picture control buttons These six buttons areSwitching Inputs Special Function Button OperationButton Backlighting FrontPanelOperation,co t’d USP 507 Menu SystemOverview of menus USP 507 Front Panel Operation NextUsing the menus User presetsSave a user preset Recall a user presetInput configuration Settings for each signal formatOutput configuration Press Next or Menu to return to the Output ConfigurationImage capture/recall To capture an imageTo recall an image Advanced configuration To remove an image from the displayAdjust knob to turn the Auto Memory on or off. See -6 for View comm settings Edit comm settingsExit menu Setting the Front Panel Locks Executive Modes Scan converter configurationEnabling or disabling Executive mode 1 from the front panel Setting Up the USP 507 to Work with a Matrix Switcher USP 507 connected to a matrix switcherConnection must be via IP not RS-232 USP 507 Input #3 select the matrixRS-232 cable only Extron USPFour SIS Programmer’s Guide RS-232/RS-422 LinkEthernet LAN\⤀ Port Connection timeouts Using verbose modeHost-to-Processor Instructions Processor-Initiated MessagesProcessor Error Responses Using the Command/Response Table for SIS CommandsSIS Programmer’s Guide, cont’d Symbol definitions = SecamSIS Programmer’s Guide, cont’d Command Response Table for SIS Commands Command Ascii command Response Additional descriptionInput Switching and Configuration $HSRTXphas TpixApix XalinX1% Colr X1%TINTX1%CONT X1%BRITX1& Hsiz X1&VSIZX1* Zoom X1HPANX2#OPOL X2$OSYNX7%VTPO X7VSTDESX1&HSIZ ESX1&VSIZESX7&HDET ESX7&VDETAdvanced Configurations X2TESTX3&VDLY Front panel lockout executive mode\⤀PIP X5TIMEPicture in Picture Resets Information requestImage capture/recall to USP 507 flash memory Using the Command/Response Table for IP SIS Commands Command/Response Table for IP SIS Commands WX12#CV ECVEFF EAEWX12%CD ~CJECJ Ethernet data portProgrammer’s Guide, cont’dEDF ELFFive Installing the program USP 507 SoftwareStarting the program USP 507 USP 507 SoftwareUsing the Program OrientationUSP 507 Software, cont’d Control program menusFile menu Options menuTools menu Download Now USP 507 USP 507 Software Help menu Sppcp Help file’s main windowControl tab Control tab screenConfiguration tab I/O Configuration tab screenAdvanced Settings tab Advanced Features Within this sectionScan Converter tab Scan Converter tab screenImage Capture tab Status barSix Accessing the Web Pages Html OperationStart the Web browser program USP 507 Html OperationSystem Status System StatusConfiguration Pages System SettingsIP Settings fields Html Operation, cont’dDhcp radio buttons IP Address fieldGateway IP Address field Subnet Mask fieldDate/Time Settings fields Date/Time Settings fieldsScaler Settings Scaler settingsRGB delay, test pattern, and Edid selections Passwords PasswordsFirmware Upgrade Download product namefirmware version.exe buttonFile Management Choose file window with a firmware file selectedUploading files Adding a directoryOther file management activities Delete all files Click Delete AllControl Pages User ControlMemory/Input Presets PIP Setup/PIP PresetsImages Image is not yet displayedReference Information AAppendix aSpecifications Reference InformationUSP 507 Reference Information Sync Reference Information, cont’d MtbfPart Numbers and Accessories AccessoriesIncluded parts Optional I/O boardsAppendixBB Default address Ethernet ConnectionEthernet Link Ping to determine Extron IP addressConnect as a Telnet client Ping to determine Web IP addressUSP 507 Ethernet Connection Connecting to the USP 507 Open command\⤀ Ethernet Connection, cont’dTelnet tips Escape character and Esc keySubnetting a Primer GatewaysLocal and remote devices IP addresses and octetsSubnet masks and octets Determining whether devices are on the same subnetUnmasked octets are compared indicated by ? in figure B-6 Masked octets are not compared indicated by X in figure B-6USA, Canada, South America Japan Central America Europe, Africa, and the Middle East ChinaAsia Middle East

USP 507 specifications

Extron Electronics has long been a leader in the field of professional AV system design, and one of their standout products is the USP 507. The USP 507 is an advanced universal speaker processor that is engineered to elevate audio performance across a variety of applications. Designed for both commercial and residential environments, the USP 507 combines cutting-edge technology with user-friendly features to deliver superior sound quality and precise audio control.

One of the main features of the USP 507 is its comprehensive signal processing capabilities. The device supports a range of audio formats and delivers 48 kHz or 96 kHz sample rates, ensuring high fidelity in audio reproduction. It also includes a configurable 5-band equalizer per channel, allowing users to fine-tune audio output to accommodate different room acoustics and speaker types.

The USP 507 is equipped with Extron’s patented SpeedMatch technology to enhance speaker performance and optimize audio clarity. This innovative technology automatically analyzes the audio signals and adjusts various parameters to compensate for environmental conditions, ensuring consistent sound quality across all outputs.

In terms of connectivity, the USP 507 offers a wide array of input and output options. It includes both balanced and unbalanced audio inputs to facilitate seamless integration with other audio equipment. Furthermore, the device provides multiple output zones, enabling simultaneous audio distribution to different areas within a facility.

The USP 507 features intuitive software for simplified setup and operation. The Extron Toolbelt application allows users to configure, manage, and monitor the speaker processor through an easy-to-navigate interface. This software enhances user experience by providing real-time diagnostics and seamless integration with other Extron devices.

Durability and reliability are also hallmarks of the USP 507. Built with high-quality materials, it is designed to withstand the demands of professional use while ensuring long-lasting performance. Additionally, the device comes equipped with advanced thermal management features to prevent overheating during extended operations.

In summary, the Extron USP 507 is a versatile universal speaker processor that combines advanced signal processing technologies, a user-friendly interface, and robust construction. Its ability to deliver superior audio performance makes it an ideal choice for various applications, ranging from corporate environments to high-end residential setups. With its comprehensive features and reliable performance, the USP 507 stands out as an essential tool for audio professionals seeking to enhance their sound experience.