Extron electronic USP 507 manual Reference Information, cont’d, Mtbf

Page 88

Reference Information, cont’d

General

Power

100 VAC to 240 VAC, 50-60 Hz, 30 watts, internal

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing

 

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

Cooling

Convection, vents on sides and top

Mounting

 

Rack mount

Yes, with included brackets.

Furniture mount

Yes, with optional under-desk or through-desk mounting kit

Enclosure type

Metal

Enclosure dimensions

1.7" H x 17.5" W x 12.0" D (1U high, full rack wide)

 

(4.3 cm H x 44.4 cm W x 30.5 cm D)

 

(Depth excludes connectors and knobs.)

Product weight

6.8 lbs (3.1 kg)

Shipping weight

11 lbs (5 kg)

DIM weight

12 lbs (6 kg)

Vibration

ISTA 1A in carton (International Safe Transit Association)

Regulatory compliance

 

Safety

CE, c-UL, UL

EMI/EMC

CE, C-tick, FCC Class A, ICES, VCCI

MTBF

30,000 hours

Warranty

3 years parts and labor

NAll nominal levels are at ±10%.

NSpecifications are subject to change without notice.

A-4 USP 507 • Reference Information

Image 88
Contents Universal Signal Processor USPPrecautions Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschFCC Class a Notice Table of Contents Table of Contents, cont’d Installing and Starting the Signal Processing USP 507 Table of Contents IiiIv USP 507 Table of Contents One Introduction About this ManualAbout the USP USP 507 IntroductionDefinitions Features Introduction, cont’dUSP 507 Introduction Two Installationstallation, cont’d UL/Safety RequirementsImportant safety instructions USP 507 InstallationTabletop placement Mounting the USPUL guidelines for rack mounted devices Rack mountingRear Panel Features and Connections Installation, cont’dPower and video input connections Output, user interface, and control connections Installation and cabling Resetting the Unit with the Reset Button Powering UpDefault display cycle USP 507 Reset Mode Summary Mode Activation Result Purpose/NotesThree Front Panel Operation Front Panel OverviewSpecial function buttons These four buttons are Picture control buttons These six buttons areSpecial Function Button Operation Switching InputsButton Backlighting USP 507 Menu System FrontPanelOperation,co t’dOverview of menus USP 507 Front Panel Operation NextUsing the menus User presetsSave a user preset Recall a user presetInput configuration Settings for each signal formatOutput configuration Press Next or Menu to return to the Output ConfigurationTo capture an image Image capture/recallTo recall an image Advanced configuration To remove an image from the displayAdjust knob to turn the Auto Memory on or off. See -6 for Edit comm settings View comm settingsExit menu Scan converter configuration Setting the Front Panel Locks Executive ModesEnabling or disabling Executive mode 1 from the front panel Setting Up the USP 507 to Work with a Matrix Switcher USP 507 connected to a matrix switcherConnection must be via IP not RS-232 USP 507 Input #3 select the matrixRS-232 cable only Extron USPFour RS-232/RS-422 Link SIS Programmer’s GuideEthernet LAN\⤀ Port Connection timeouts Using verbose modeHost-to-Processor Instructions Processor-Initiated MessagesUsing the Command/Response Table for SIS Commands Processor Error ResponsesSIS Programmer’s Guide, cont’d Symbol definitions = SecamSIS Programmer’s Guide, cont’d Command Response Table for SIS Commands Command Ascii command Response Additional descriptionInput Switching and Configuration $HSRTXphas TpixApix XalinX1% Colr X1%TINTX1%CONT X1%BRITX1& Hsiz X1&VSIZX1* Zoom X1HPANX2#OPOL X2$OSYNX7%VTPO X7VSTDESX1&HSIZ ESX1&VSIZESX7&HDET ESX7&VDETAdvanced Configurations X2TESTX3&VDLY Front panel lockout executive mode\⤀X5TIME PIPPicture in Picture Information request ResetsImage capture/recall to USP 507 flash memory Using the Command/Response Table for IP SIS Commands Command/Response Table for IP SIS Commands WX12#CV ECVEFF EAEWX12%CD ~CJECJ Ethernet data portProgrammer’s Guide, cont’dEDF ELFFive Installing the program USP 507 SoftwareStarting the program USP 507 USP 507 SoftwareUsing the Program OrientationUSP 507 Software, cont’d Control program menusFile menu Options menuTools menu Download Now USP 507 USP 507 Software Help menu Sppcp Help file’s main windowControl tab Control tab screenConfiguration tab I/O Configuration tab screenAdvanced Settings tab Advanced Features Within this sectionScan Converter tab Scan Converter tab screenImage Capture tab Status barSix Accessing the Web Pages Html OperationStart the Web browser program USP 507 Html OperationSystem Status System StatusConfiguration Pages System SettingsIP Settings fields Html Operation, cont’dDhcp radio buttons IP Address fieldGateway IP Address field Subnet Mask fieldDate/Time Settings fields Date/Time Settings fieldsScaler Settings Scaler settingsRGB delay, test pattern, and Edid selections Passwords PasswordsFirmware Upgrade Download product namefirmware version.exe buttonFile Management Choose file window with a firmware file selectedUploading files Adding a directoryOther file management activities Delete all files Click Delete AllControl Pages User ControlMemory/Input Presets PIP Setup/PIP PresetsImages Image is not yet displayedReference Information AAppendix aReference Information SpecificationsUSP 507 Reference Information Sync Reference Information, cont’d MtbfPart Numbers and Accessories AccessoriesIncluded parts Optional I/O boardsAppendixBB Default address Ethernet ConnectionEthernet Link Ping to determine Extron IP addressPing to determine Web IP address Connect as a Telnet clientUSP 507 Ethernet Connection Connecting to the USP 507 Open command\⤀ Ethernet Connection, cont’dTelnet tips Escape character and Esc keySubnetting a Primer GatewaysLocal and remote devices IP addresses and octetsSubnet masks and octets Determining whether devices are on the same subnetUnmasked octets are compared indicated by ? in figure B-6 Masked octets are not compared indicated by X in figure B-6Europe, Africa, and the Middle East China USA, Canada, South America Japan Central AmericaAsia Middle East

USP 507 specifications

Extron Electronics has long been a leader in the field of professional AV system design, and one of their standout products is the USP 507. The USP 507 is an advanced universal speaker processor that is engineered to elevate audio performance across a variety of applications. Designed for both commercial and residential environments, the USP 507 combines cutting-edge technology with user-friendly features to deliver superior sound quality and precise audio control.

One of the main features of the USP 507 is its comprehensive signal processing capabilities. The device supports a range of audio formats and delivers 48 kHz or 96 kHz sample rates, ensuring high fidelity in audio reproduction. It also includes a configurable 5-band equalizer per channel, allowing users to fine-tune audio output to accommodate different room acoustics and speaker types.

The USP 507 is equipped with Extron’s patented SpeedMatch technology to enhance speaker performance and optimize audio clarity. This innovative technology automatically analyzes the audio signals and adjusts various parameters to compensate for environmental conditions, ensuring consistent sound quality across all outputs.

In terms of connectivity, the USP 507 offers a wide array of input and output options. It includes both balanced and unbalanced audio inputs to facilitate seamless integration with other audio equipment. Furthermore, the device provides multiple output zones, enabling simultaneous audio distribution to different areas within a facility.

The USP 507 features intuitive software for simplified setup and operation. The Extron Toolbelt application allows users to configure, manage, and monitor the speaker processor through an easy-to-navigate interface. This software enhances user experience by providing real-time diagnostics and seamless integration with other Extron devices.

Durability and reliability are also hallmarks of the USP 507. Built with high-quality materials, it is designed to withstand the demands of professional use while ensuring long-lasting performance. Additionally, the device comes equipped with advanced thermal management features to prevent overheating during extended operations.

In summary, the Extron USP 507 is a versatile universal speaker processor that combines advanced signal processing technologies, a user-friendly interface, and robust construction. Its ability to deliver superior audio performance makes it an ideal choice for various applications, ranging from corporate environments to high-end residential setups. With its comprehensive features and reliable performance, the USP 507 stands out as an essential tool for audio professionals seeking to enhance their sound experience.