TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Hopper Display Lights not on | 3. Circuit Breaker | (A) The circuit breaker must not be |
(cont.) |
| tripped. |
|
| (B) Refer to Service - Circuit Breaker |
|
| for testing procedures. See page |
|
| 27. |
| 4. Lamps | Remove the lamps and check for |
|
| continuity across the base and tip. |
|
| Replace if necessary. |
| 5.Transformer | Refer to Service - Transformer for |
|
| testing procedures. See page 49. |
| 6. Lamp Holder/Socket Assy | Refer to Service - Lamp Holder/Sock- |
|
| et Assembly for testing procedures. |
|
| See page 44. |
Auger Motor won’t turn | 1. Auger ON/OFF Switch(es) | (A) The auger switch must be in the |
|
| “ON” position. |
|
| (B) Refer to Service - Auger ON/OFF |
|
| Switch(es) for testing procedures. |
|
| See page 26. |
| 2. Auger Motor Capacitor(s) | Refer to Service - Auger Motor |
|
| Capacitor(s) for testing procedures. |
|
| See page 23. |
| 3. | Auger Motor(s) |
Fan not spinning (With adjustment | 1. | Fan Motor |
Board L.E.D.s ON steadily for two |
|
|
minutes) |
|
|
Fan spins after compressor shuts | 1. | Time Delay |
off |
|
|
Refer to Service - Auger Motor(s) for testing procedures. See page 22.
Refer to Service - Fan Motor for test- ing procedures. See page 39.
The fan motor will run for approxi- mately two minutes after compressor shuts off.