Bunn CDS-3 service manual Cooling Drum Alignment, Symptoms

Page 35

SERVICE (cont.)

COOLING DRUM ALIGNMENT

Ledge

Boss

Legs

FIG. 23 COOLING DRUM SHIPPING SUPPORT

The “A” shaped Cooling Drum Shipping Supports, removed during Initial Set-Upshould be kept and used as a tool to reset the alignment of the cooling drums should it ever be required.

Symptoms:

Squeaky Operation, hopper lifts or won’t seat properly, hopper is pushed to one side or the other.

To check alignment

1.Place the “A” shaped support on the auger shaft with the ledge under the cooling drum.

2.Lift the cooling drum while rotating the support into a vertical position. The boss on the very bottom will drop into the hopper drip tray’s drain hole.

FIG. 24 CHECKING ALIGNMENT

P1510

 

When in its proper position, the cooling drum will cause a slight pressure on the hopper drip tray drain hole and the two legs will be equidistant from the hopper drip tray.

If adjustment is needed, remove the support and gently force the free end of the evaporator in the direction the adjustment is needed.

Reinstall the support, check the alignment, and read- just the cooling drums as required.  

35

27646 122200

 

Image 35
Contents Post Office BOX SPRINGFIELD, Illinois CDS-2 CDS-3Introduction Contents28720.0000 27443.0000 User Notices12559.0003 00986.0002 CDSA-2 Only User Notices27664.0000 Electrical Requirements Site preparationPlace Inside of each auger shaft Initial setupHand Each cooling drum seal As shownApproximately Operating Controls Operating Controls DAY/NIGHT TimerSetting Time Setting Night Time ModeUsing the Dispenser for Cold Liquid Products Using the Dispenser for GRANITA-TYPE ProductsOther Recommendations for Your Dispenser Recommended Daily Cleaning Sugar & Alcohol products Lubrication Recommended Weekly CleaningFaucet Handles DisassemblyAssembly LubricationSnap it onto the assembly Auger assembly & Disassembly Early Augers onlyProblem Probable Cause Remedy TroubleshootingHopper Display Lights not on Circuit Breaker Auger Motor won’t turn Auger ON/OFF SwitchesAuger Motor Capacitors Refer to Service Auger Motor Time DelayWith an extension cord. Refer to Compressor not running Power cordIng procedures. See With adjustment Board L.E.D.sProblem Probable Cause Become unusual. Auger Motors ProblemComponent Access ServiceLocation Test ProceduresAuger Motors Auger Motor Capacitors Auger Motor CapacitorAuger Shaft Assembly Auger Shaft AssemblyService Auger Shaft ASSEMBLYcont Volts ac for 120 volt models Volts ac for 230 volt models Auger ON/OFF SwitchesCircuit Breaker Remove the wires from the circuit breakerCompressor Start Relay Refer to FIG Dispenser chassis Two wire 230 volt modelsConnect the black wire from the compressor Properly discharged before proceeding120V Dispensers Remove run capacitor and discard Refer to a and reconnect the wiresCompressor Thermal P1819 Overload Protector Location Compressor & Components CDS-3 RED from Relay T2 WHI from Relay T4 BLK from Relay T-5 Disconnect the fan leads from the main wiring harness Refer to a and reconnect the wires to the compressor Compressor Relay Terminals Contactor Electronic Control Cooling Drum Alignment SymptomsDAY/NIGHT Switch Dispenser ON/OFF Switch Dispenser ON/OFF SwitchElectronic Control Electronic ControlFAN Use cable ties to secure wires away from fan bladesFuse Holder Fuse and Fuse HolderICE/OFF/NO ICE Switches ICE/OFF/NO ICE SwitchesLamp Cord Assy Lamp Cord AssyUpper left side of the auger covers Test Procedures Lamp Cord ConnectorInside the hopper covers Lamp HOLDER/SOCKET AssemblyE.D./ Adjustment Board D./ADJUSTMENT BoardSolenoids SolenoidsTemperature Sensor Temperature SensorTorque Sensor Circuit Board P1341 Location Torque Sensor Circuit BoardRemove transformer and discard TransformerVoltage Divider ServiceCoolant Schematic Diagram CDS-2 Prior to S/N CDS Coolant Schematic Diagram CDS-3CDS 0019500 Up 27646 27646 Schematic Wiring Diagram for CDS-2 PAF Schematic Wiring Diagram for CDSA-2 PAF 27646 27646 27646
Related manuals