Bunn Compressor & Components CDS-3, Compressor Thermal P1819 Overload Protector Location

Page 31
FIG. 16 COMPRESSOR &
COMPONENT LOCATIONS

SERVICE (cont.)

COMPRESSOR & COMPONENTS (CDS-3)

1

2 3

P1558.30

Location:

The compressor assy is located inside the front of the dispenser chassis.

4 5

6

7

FIG. 17 COMPRESSOR THERMAL P1819 OVERLOAD PROTECTOR LOCATION

1.Compressor Start Relay

2.Compressor Start Capacitor

3.Compressor Run Capacitor

4.Thermal Overload Protector

5.Overload Protector Retainer

6.Compressor Terminal Cover

7.Compressor Terminal Cover Retainer

Test Procedures:

Compressor Start Relay: Refer to FIG. 17

WARNING: The compressor capacitors must be prop- erly discharged before proceeding.

1.Disconnect the dispenser from the power source.

2.Remove the compressor terminal cover retainer

(7) and compressor terminal cover (6).

3.Disconnect the black wire to the thermal overload protector (4), the white and black or red wires to the compressor.

4.With a voltmeter, check voltage across the black wire removed from the thermal overload protector and the white wire with the ON/OFF switch in the “ON” position, DAY/NIGHT switch in the “DAY” position and the ICE/OFF/NO ICE switch in the “ICE” posi- tion. Connect the dispenser to the power source. The indication must be:

a)120 volts ac for 120 volt models.

b)230 volts ac for 230 volt models.

5.Disconnect the dispenser from the power source. If voltage is present as described, proceed to #6. If voltage is not present as described, refer to the Wiring Diagram and check the dispenser wiring harness.

6.Disconnect the two black wires from the compres- sor start capacitor.

7.Check for continuity across contacts 1 & 2 of the relay.

If continuity is present as described, the compressor start relay is operating properly.

If continuity is not present as described, replace re- lay.

Compressor:

1.With the compressor start relay (1) removed, discon- nect the black or red wire from the compressor.

2.Check for continuity across the terminal on the compressor and the left pin on the compressor.

If continuity is present as described, the electrical part of the compressor is operating properly.

If continuity is not present as described, replace the compressor.

Thermal Overload Protector:

1.Check for continuity across the terminals on the thermal overload protector.

If continuity is present as described, the thermal over- load protector is operating properly.

If continuity is not present as described, replace the thermal overload protector.

Compressor Start Capacitor:

1.Check for continuity across the terminals on the compressor start capacitor.

If continuity is present as described, the start capacitor is operating properly.

If continuity is not present as described, replace the capacitor.

31

27646

122200

 

Image 31
Contents Post Office BOX SPRINGFIELD, Illinois CDS-2 CDS-3Introduction Contents12559.0003 00986.0002 User Notices28720.0000 27443.0000 27664.0000 User NoticesCDSA-2 Only Electrical Requirements Site preparationPlace Inside of each auger shaft Initial setupHand Each cooling drum seal As shownApproximately Operating Controls Operating Controls DAY/NIGHT TimerSetting Time Setting Night Time ModeUsing the Dispenser for Cold Liquid Products Using the Dispenser for GRANITA-TYPE ProductsOther Recommendations for Your Dispenser Recommended Daily Cleaning Sugar & Alcohol products Lubrication Recommended Weekly CleaningFaucet Handles DisassemblyAssembly LubricationSnap it onto the assembly Auger assembly & Disassembly Early Augers onlyProblem Probable Cause Remedy TroubleshootingHopper Display Lights not on Circuit Breaker Auger Motor won’t turn Auger ON/OFF SwitchesAuger Motor Capacitors Refer to Service Auger Motor Time DelayWith an extension cord. Refer to Compressor not running Power cordIng procedures. See With adjustment Board L.E.D.sProblem Probable Cause Become unusual. Auger Motors ProblemComponent Access ServiceAuger Motors Test ProceduresLocation Auger Motor Capacitors Auger Motor CapacitorAuger Shaft Assembly Auger Shaft AssemblyService Auger Shaft ASSEMBLYcont Volts ac for 120 volt models Volts ac for 230 volt models Auger ON/OFF SwitchesCircuit Breaker Remove the wires from the circuit breaker Compressor Start Relay Refer to FIG Dispenser chassis Two wire 230 volt models Connect the black wire from the compressor Properly discharged before proceeding120V Dispensers Remove run capacitor and discard Refer to a and reconnect the wiresCompressor Thermal P1819 Overload Protector Location Compressor & Components CDS-3Refer to a and reconnect the wires to the compressor Disconnect the fan leads from the main wiring harnessRED from Relay T2 WHI from Relay T4 BLK from Relay T-5 Compressor Relay Terminals Contactor Electronic Control Cooling Drum Alignment SymptomsDAY/NIGHT Switch Dispenser ON/OFF Switch Dispenser ON/OFF SwitchElectronic Control Electronic ControlFAN Use cable ties to secure wires away from fan bladesFuse Holder Fuse and Fuse HolderICE/OFF/NO ICE Switches ICE/OFF/NO ICE SwitchesLamp Cord Assy Lamp Cord AssyUpper left side of the auger covers Test Procedures Lamp Cord ConnectorInside the hopper covers Lamp HOLDER/SOCKET AssemblyE.D./ Adjustment Board D./ADJUSTMENT BoardSolenoids SolenoidsTemperature Sensor Temperature SensorTorque Sensor Circuit Board P1341 Location Torque Sensor Circuit BoardRemove transformer and discard TransformerVoltage Divider ServiceCoolant Schematic Diagram CDS-2 Prior to S/N CDS Coolant Schematic Diagram CDS-3CDS 0019500 Up 27646 27646 Schematic Wiring Diagram for CDS-2 PAF Schematic Wiring Diagram for CDSA-2 PAF 27646 27646 27646