Bunn CDS-3 Auger ON/OFF Switches, Volts ac for 120 volt models Volts ac for 230 volt models

Page 26

SERVICE (cont.)

AUGER ON/OFF SWITCHES

FIG. 7 AUGER ON/OFF SWITCHES

P1343

 

Location:

The auger switches are located inside the dispenser drawer.

Test Procedures:

1.Disconnect the dispenser from the power source.

2.Disconnect the white/green wire from the switch to be tested and white/black wire from contactor located on the outside bottom of the component bracket .

3.With a voltmeter, check the voltage across the white/ green and the white/black wires and the “ON/OFF” switch in the “ON” position. Connect the dispenser to the power source. The indication must be:

a)120 volts ac for 120 volt models.

b)230 volts ac for 230 volt models.

4.Disconnect the dispenser from the power source.

If voltage is present as described, reconnect the white/ black wire to the contactor and proceed to #5.

If voltage is not present as described, refer to the Wiring Diagram and check the dispenser wiring harness.

5.Remove the white/blue wire from the right auger switch, the white/brown wire from the left auger switch, or the grey wire from the center auger switch.

6.With the auger switch to be tested in the “ON” position check for continuity across the terminals. Continuity must not be present when the switch is in the “OFF” position.

If continuity is present as described, the auger switch is operating properly.

If continuity is not present as described, replace the auger switch.

Removal and Replacement:

1.Pull the dispenser drawer out until the drawer hits the drawer stop. Using a screwdriver gently pry up on the drawer stop and remove the drawer from the dispenser.

2.Remove the four #8-32 locking screws securing the switch panel to the drawer.

3.Lift the switch panel with wires and L.E.D./adjust- ment board out as an assembly.

4.Turn switch panel over and remove the wires from the auger switch that is to be replaced.

5.Compress the clips on the back of the control panel and gently push switch through the opening.

6.Push the new switch into the opening, with the “o” on the switch to the outside, until the clips snap into position.

7.Reconnect the wires to the switch. Refer to Fig. 8 when reconnecting wires.

8.Position the switch panel inside the drawer and secure with four #8-32 locking screws.

9.Reinstall drawer.

FIG. 8 AUGER SWITCH TERMINALS

P1336

 

26

27646 122200

 

Image 26
Contents CDS-2 CDS-3 Post Office BOX SPRINGFIELD, IllinoisContents Introduction28720.0000 27443.0000 User Notices12559.0003 00986.0002 CDSA-2 Only User Notices27664.0000 Site preparation Electrical RequirementsAs shown Initial setupHand Each cooling drum seal Place Inside of each auger shaftApproximately Operating Controls Setting Night Time Mode DAY/NIGHT TimerSetting Time Operating ControlsUsing the Dispenser for GRANITA-TYPE Products Using the Dispenser for Cold Liquid ProductsOther Recommendations for Your Dispenser Recommended Daily Cleaning Sugar & Alcohol products Recommended Weekly Cleaning LubricationLubrication DisassemblyAssembly Faucet HandlesAuger assembly & Disassembly Early Augers only Snap it onto the assemblyTroubleshooting Problem Probable Cause RemedyTime Delay Auger Motor won’t turn Auger ON/OFF SwitchesAuger Motor Capacitors Refer to Service Auger Motor Hopper Display Lights not on Circuit BreakerWith adjustment Board L.E.D.s Compressor not running Power cordIng procedures. See With an extension cord. Refer toProblem Probable Cause Problem Become unusual. Auger MotorsService Component AccessLocation Test ProceduresAuger Motors Auger Motor Capacitor Auger Motor CapacitorsAuger Shaft Assembly Auger Shaft AssemblyService Auger Shaft ASSEMBLYcont Auger ON/OFF Switches Volts ac for 120 volt models Volts ac for 230 volt modelsRemove the wires from the circuit breaker Circuit BreakerProperly discharged before proceeding Dispenser chassis Two wire 230 volt modelsConnect the black wire from the compressor Compressor Start Relay Refer to FIG120V Dispensers Refer to a and reconnect the wires Remove run capacitor and discardCompressor & Components CDS-3 Compressor Thermal P1819 Overload Protector LocationRED from Relay T2 WHI from Relay T4 BLK from Relay T-5 Disconnect the fan leads from the main wiring harnessRefer to a and reconnect the wires to the compressor Compressor Relay Terminals Contactor Electronic Control Symptoms Cooling Drum AlignmentDAY/NIGHT Switch Dispenser ON/OFF Switch Dispenser ON/OFF SwitchElectronic Control Electronic ControlUse cable ties to secure wires away from fan blades FANFuse and Fuse Holder Fuse HolderICE/OFF/NO ICE Switches ICE/OFF/NO ICE SwitchesLamp Cord Assy Lamp Cord AssyLamp Cord Connector Upper left side of the auger covers Test ProceduresLamp HOLDER/SOCKET Assembly Inside the hopper coversD./ADJUSTMENT Board E.D./ Adjustment BoardSolenoids SolenoidsTemperature Sensor Temperature SensorTorque Sensor Circuit Board Torque Sensor Circuit Board P1341 LocationTransformer Remove transformer and discardService Voltage DividerCoolant Schematic Diagram CDS-2 Coolant Schematic Diagram CDS-3 Prior to S/N CDSCDS 0019500 Up 27646 27646 Schematic Wiring Diagram for CDS-2 PAF Schematic Wiring Diagram for CDSA-2 PAF 27646 27646 27646
Related manuals
Manual 34 pages 32.1 Kb Manual 34 pages 40.35 Kb

CDS-3 specifications

The Bunn CDS-3 is a commercial coffee brewer renowned for its reliability, efficiency, and high-quality performance. Designed for busy environments such as cafés, restaurants, and convenience stores, it offers the perfect balance of capacity and functionality, making it ideal for high-demand situations.

One of the standout features of the Bunn CDS-3 is its ability to brew up to 3.8 gallons of coffee per hour. This impressive capacity meets the needs of busy establishments where a constant supply of fresh coffee is crucial. The brewer’s stainless steel construction not only ensures durability but also maintains temperature, thus preserving the coffee’s rich flavor and aroma.

The CDS-3 incorporates Bunn's patented brewing technology, including the "Pour-Over" method. This feature allows for easy operation and contributes to the even extraction of coffee grounds. The machine is equipped with a pre-infusion mode that saturates coffee grounds before brewing, enhancing extraction for a fuller, more complex flavor profile.

Temperature control is another vital characteristic of the Bunn CDS-3. It maintains the water temperature between 195°F to 205°F, the ideal range for optimal coffee brewing. The brewer’s internals are designed for rapid heating, ensuring that the water reaches the desired temperature quickly and consistently, which is essential for high-quality coffee production.

In terms of usability, the Bunn CDS-3 offers an intuitive interface, allowing staff to operate it with minimal training. The front-access design not only simplifies maintenance, but also makes it easy to refill water and perform routine cleaning. Furthermore, the large capacity coffee pots ensure that the brewed coffee can be stored efficiently, minimizing waste.

Equipped with a unique spray head system, the Bunn CDS-3 ensures uniform saturation of the coffee grounds. This feature supports optimal extraction, allowing users to produce a rich and flavorful brew that keeps customers coming back for more.

In summary, the Bunn CDS-3 is a well-engineered, commercial-grade coffee brewer that excels in high-demand environments. Its robust construction, advanced brewing technology, consistent temperature control, and user-friendly design make it a favorite among coffee enthusiasts and professionals alike, affirming its reputation as a reliable and effective solution for coffee brewing needs. Whether for a bustling café or a catering service, the Bunn CDS-3 delivers a consistently great cup of coffee every time.