Bunn CDS-3 Compressor not running Power cord, With an extension cord. Refer to, Fuse, Contactor

Page 18

TROUBLESHOOTING (cont.)

 

 

PROBLEM

PROBABLE CAUSE

REMEDY

Compressor not running

1. Power cord

The dispenser must not be connected

(With Adjustment Board L.E.D.s ON

 

with an extension cord. Refer to

steadily for two minutes)

 

Electrical Requirements.

 

2. Fuse

Refer to Service - Fuse and Fuse

 

 

Holder for testing procedures. See

 

 

page 40.

 

3. Contactor

Refer to Service - Contactor for test-

 

 

ing procedures. See page 34.

 

4. Electronic Control

Refer to Service - Electronic Control

 

 

for testing procedures. See page

 

 

38.

 

5. Compressor Start Relay

Refer to Service - Compressor Start

 

 

Relay for testing procedures. See

 

 

page 28 (CDS-2) or 31 (CDS-3).

 

6. Thermal Overload Protector

Refer to Service - Compressor Ther-

 

 

mal Overload Protector for testing

 

 

procedures. See page 28 (CDS-2)

 

 

or 31 (CDS-3).

 

7. Compressor Start Capacitor

Refer to Service - Compressor Start

 

 

Capacitor for testing procedures. See

 

 

page 28 (CDS-2) or 31 (CDS-3).

 

8. Compressor

Refer to Service - Compressor for

 

 

testing procedures. See page 28

 

 

(CDS-2) or 31 (CDS-3).

Compressor runs but will not cool

1. Auger not turning

Refer to Troubleshooting - Auger Mo-

(With adjustment Board L.E.D.s

 

tor Won’t Turn on previous page.

flashing once every 4 seconds)

 

 

Compressor runs but will not cool

1. Temperature Sensor Assembly

Refer to Service - Temperature Sen-

(With adjustment Board L.E.D.s

 

sor Assembly for testing procedures.

flashing twice every 4 seconds)

 

See page 47.

Compressor runs but will not cool

1. Torque Sensor Circuit Board

Refer to Service - Torque Sensor

(With adjustment Board L.E.D.s

 

Circuit Board for testing procedures.

flashing 3, or 4 times every 4

 

See page 48.

seconds)

 

 

18

27646 122200

 

Image 18
Contents CDS-2 CDS-3 Post Office BOX SPRINGFIELD, IllinoisContents IntroductionUser Notices 12559.0003 00986.000228720.0000 27443.0000 User Notices 27664.0000CDSA-2 Only Site preparation Electrical RequirementsAs shown Initial setupHand Each cooling drum seal Place Inside of each auger shaftApproximately Operating Controls Setting Night Time Mode DAY/NIGHT TimerSetting Time Operating ControlsUsing the Dispenser for GRANITA-TYPE Products Using the Dispenser for Cold Liquid ProductsOther Recommendations for Your Dispenser Recommended Daily Cleaning Sugar & Alcohol products Recommended Weekly Cleaning LubricationLubrication DisassemblyAssembly Faucet Handles Auger assembly & Disassembly Early Augers only Snap it onto the assemblyTroubleshooting Problem Probable Cause RemedyTime Delay Auger Motor won’t turn Auger ON/OFF SwitchesAuger Motor Capacitors Refer to Service Auger Motor Hopper Display Lights not on Circuit BreakerWith adjustment Board L.E.D.s Compressor not running Power cordIng procedures. See With an extension cord. Refer toProblem Probable Cause Problem Become unusual. Auger MotorsService Component AccessTest Procedures Auger MotorsLocation Auger Motor Capacitor Auger Motor CapacitorsAuger Shaft Assembly Auger Shaft AssemblyService Auger Shaft ASSEMBLYcont Auger ON/OFF Switches Volts ac for 120 volt models Volts ac for 230 volt modelsRemove the wires from the circuit breaker Circuit BreakerProperly discharged before proceeding Dispenser chassis Two wire 230 volt modelsConnect the black wire from the compressor Compressor Start Relay Refer to FIG120V Dispensers Refer to a and reconnect the wires Remove run capacitor and discardCompressor & Components CDS-3 Compressor Thermal P1819 Overload Protector LocationDisconnect the fan leads from the main wiring harness Refer to a and reconnect the wires to the compressorRED from Relay T2 WHI from Relay T4 BLK from Relay T-5 Compressor Relay Terminals Contactor Electronic Control Symptoms Cooling Drum AlignmentDAY/NIGHT Switch Dispenser ON/OFF Switch Dispenser ON/OFF SwitchElectronic Control Electronic ControlUse cable ties to secure wires away from fan blades FANFuse and Fuse Holder Fuse HolderICE/OFF/NO ICE Switches ICE/OFF/NO ICE SwitchesLamp Cord Assy Lamp Cord AssyLamp Cord Connector Upper left side of the auger covers Test ProceduresLamp HOLDER/SOCKET Assembly Inside the hopper coversD./ADJUSTMENT Board E.D./ Adjustment BoardSolenoids SolenoidsTemperature Sensor Temperature SensorTorque Sensor Circuit Board Torque Sensor Circuit Board P1341 LocationTransformer Remove transformer and discardService Voltage DividerCoolant Schematic Diagram CDS-2 Coolant Schematic Diagram CDS-3 Prior to S/N CDSCDS 0019500 Up 27646 27646 Schematic Wiring Diagram for CDS-2 PAF Schematic Wiring Diagram for CDSA-2 PAF 27646 27646 27646