TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Compressor not running | 1. Power cord | The dispenser must not be connected |
(With Adjustment Board L.E.D.s ON |
| with an extension cord. Refer to |
steadily for two minutes) |
| Electrical Requirements. |
| 2. Fuse | Refer to Service - Fuse and Fuse |
|
| Holder for testing procedures. See |
|
| page 40. |
| 3. Contactor | Refer to Service - Contactor for test- |
|
| ing procedures. See page 34. |
| 4. Electronic Control | Refer to Service - Electronic Control |
|
| for testing procedures. See page |
|
| 38. |
| 5. Compressor Start Relay | Refer to Service - Compressor Start |
|
| Relay for testing procedures. See |
|
| page 28 |
| 6. Thermal Overload Protector | Refer to Service - Compressor Ther- |
|
| mal Overload Protector for testing |
|
| procedures. See page 28 |
|
| or 31 |
| 7. Compressor Start Capacitor | Refer to Service - Compressor Start |
|
| Capacitor for testing procedures. See |
|
| page 28 |
| 8. Compressor | Refer to Service - Compressor for |
|
| testing procedures. See page 28 |
|
|
|
Compressor runs but will not cool | 1. Auger not turning | Refer to Troubleshooting - Auger Mo- |
(With adjustment Board L.E.D.s |
| tor Won’t Turn on previous page. |
flashing once every 4 seconds) |
|
|
Compressor runs but will not cool | 1. Temperature Sensor Assembly | Refer to Service - Temperature Sen- |
(With adjustment Board L.E.D.s |
| sor Assembly for testing procedures. |
flashing twice every 4 seconds) |
| See page 47. |
Compressor runs but will not cool | 1. Torque Sensor Circuit Board | Refer to Service - Torque Sensor |
(With adjustment Board L.E.D.s |
| Circuit Board for testing procedures. |
flashing 3, or 4 times every 4 |
| See page 48. |
seconds) |
|
|