Hoshizaki DCM-500BAH-OS service manual DCM-500BWH-OS, Potable Water Water Cooled Condenser

Page 8

4. DCM-500BWH-OS

AC SUPPLY VOLTAGE

115/60/1

 

 

 

 

 

 

 

 

COMPRESSOR

120 V

7.9 RLA

51 LRA

 

 

GEAR MOTOR

 

120 V

1.6 FLA

1/6 HP

 

 

AGITATING MOTOR

120 V

0.9 FLA

55 W

 

 

 

DISPENSING MOTOR

120 V

0.9 FLA

55 W

 

 

 

OTHERS

 

120 V

0.2 A

 

 

 

 

 

MAXIMUM FUSE SIZE

20 A

 

 

 

 

 

 

 

 

MAX. HACR BREAKER (USA ONLY)

20 A

 

 

 

 

 

 

 

 

MAX. CIRC. BREAKER (CANADA ONLY)

20 A

 

 

 

 

 

 

 

 

MINIMUM CIRCUIT AMPACITY

20 A

 

 

 

 

 

 

 

 

APPROXIMATE ICE PRODUCTION

Ambient

 

 

WATER TEMP. (°F)

 

 

PER 24 HR.

 

Temp. (°F)

50

 

 

70

90

 

 

lbs./day ( kg/day )

70

 

* 567

257

 

549

249

539

244

 

Reference without * marks

80

 

529

240

 

519

235

509

231

 

 

 

90

 

500

227

 

* 495

224

481

218

 

SHAPE OF ICE

 

100

 

472

214

 

464

210

* 428

194

 

 

Cubelet

(Compressed Flake Ice)

 

 

 

ICE QUALITY

 

Approx. 89% Ice (90/70° F, CONDUCTIVITY 200 µs/cm)

APPROXIMATE STORAGE CAPACITY

40 lbs.

 

 

 

 

 

 

 

 

 

ELECTRIC & WATER CONSUMPTION

90/70°F

70/50°F

 

 

 

 

 

ELECTRIC

W (kWH/100 lbs.)

930 (4.8)

985 (4.0)

 

 

 

 

 

 

POTABLE WATER

56 (12)

65 (12)

 

 

 

 

 

 

WATER - COOLED CONDENSER

465 (100)

285 (52)

 

 

 

 

 

 

gal./24HR

(gal./100 lbs.)

 

 

 

 

 

 

 

 

 

 

EXTERIOR DIMENSIONS (WxDxH)

26" x 22-1/2" x 40" (661 x 571 x 1016 mm)

 

 

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

 

 

WEIGHT

 

Net 245 lbs. (111 kg), Shipping 269 lbs. (122 kg)

CONNECTIONS - ELECTRIC

Permanent Connection

 

 

 

 

 

- WATER SUPPLY

Inlet

1/2" FPT

Condenser Inlet 1/2"FPT

 

 

- DRAIN

Outlet

3/4" FPT x2 Condenser Outlet 3/8" FPT

ICE MAKING SYSTEM

Auger type

 

 

 

 

 

 

 

 

HARVESTING SYSTEM

Direct Driven Auger ( 1/6 HP Gear Motor )

 

 

ICE MAKING WATER CONTROL

Float Switch

 

 

 

 

 

 

 

COOLING WATER CONTROL

Automatic Water Regulator

 

 

 

 

DISPENSE CONTROL SYSTEM

Photoelectric Sensor (Infrared)

 

 

 

 

BIN CONTROL SYSTEM

Mechanical Bin Control ( Proximity Sw. )

 

 

COMPRESSOR

Hermetic, Model RS43C2E-CAA-219

 

 

 

CONDENSER

 

Water Cooled, Double Tube Type

 

 

 

EVAPORATOR

 

Copper Tube on Cylinder

 

 

 

 

 

REFRIGERANT CONTROL

Thermostatic Expansion Valve

 

 

 

 

REFRIGERANT CHARGE

R404A

 

14.1 oz. (400g)

 

 

 

 

DESIGN PRESSURE

High 460 PSIG

 

 

Low 290 PSIG

 

 

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-out Relay

 

 

 

 

COMPRESSOR PROTECTION

Auto-reset Overload Protector

 

 

 

 

GEAR MOTOR PROTECTION

Auto-reset Thermal Protector

 

 

 

 

 

 

Fuse

 

 

 

 

 

 

 

 

 

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

 

 

LOW WATER PROTECTION

Float Switch and Timer

 

 

 

 

 

ACCESSORIES - SUPPLIED

Spare Fuse

 

 

 

 

 

 

 

 

- REQUIRED

Legs

 

 

 

 

 

 

 

 

 

OPERATING CONDITIONS

VOLTAGE RANGE

 

 

 

 

104-127 V

 

 

AMBIENT TEMP.

 

 

 

 

45-100°F

 

 

WATER SUPPLY TEMP.

 

 

45-90°F

 

 

WATER SUPPLY PRESSURE

 

10-113 PSIG

Note: We reserve the right to make changes in specifications

and

design

without prior

notice.

 

 

 

 

 

 

 

 

 

 

8

Image 8
Contents DCM-500BAH DCM-500BAH-OS DCM-500BWH DCM-500BWH-OS Hoshizaki AMERICA, INC Contents Page Specifications Icemaker DCM-500BAHDCM-500BAH-OS Water TEMP. FDCM-500BWH Water TEMP. FDCM-500BWH-OS Potable Water Water Cooled CondenserII. General Information Construction Spout a Expansion Valve Spout B Evaporator Assembly Ice Making Unit DCM-500BAH-OS, DCM-500BWH-OSSequence of Operation Startup Control Board Control Board Layout DCM-500BAH, DCM-500BWH Control BoardPart Number 2A2649-01 Features LED LightsControls and Adjustments Portion Control Control Board Check ProcedurePower Supply Ice Making ComponentsDispensing Components DCM-500BAH, DCM-500BWH Float Switch DCM-500BAH-OS Inlet Water Valve Water Supply Wiring Diagrams Wire Color CodeDCM-500BAH-OS, DCM-500BWH-OS Sequence of Electrical Circuit Ice Making DCM-500BWH-OSIce Purge Cycle DCM-500BWH-OSFreeze Cycle Hour Drain Cycle / Drain Switch Shutdown Low Water Safety High Pressure Switch Sequence of Electrical Circuit Dispensing Continuous DispensePortion Dispense Performance Data ICE ProductionTotal IV. Service Diagnosis Diagnostic Procedure Ice Production Check Diagnostic Charts No Ice ProductionProblem Possible Cause Remedy Problem Possible Cause Remedy Low Ice Production Other Dispensing Opti Serve OS Sensors 5c. Water Dispensing 5a. Ice Dispensing Continuous Mode5b. Ice Dispensing Portion Mode Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery BrazingEvacuation and Recharge R-404A Removal and Replacement of Compressor Removal and Replacement of Expansion Valve Removal and Replacement of Evaporator Assembly Components Removal and Replacement of Extruding Head Upper Bearing Wear CheckRemoval and Replacement of Auger Removal and Replacement of EvaporatorPage 5b. Lower Housing Removal and Replacement of Gear Motor Page Removal and Replacement of Water-Cooled Condenser Page Adjustment of Water Regulating Valve Water-Cooled Model Only Removal and Replacement of Fan MotorRemoval and Replacement of Inlet or Dispensing Water Valve Removal and Replacement of Drain ValveDispensing or Agitating Motor Removal and Replacement of Dispensing SystemDispensing Auger and Agitator Page VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Water SystemSanitizing Solution Dispensing ComponentsBin Control Bracket Snap Pin Maintenance Frequency Area TaskPreparing the Icemaker for Long Storage