E. Performance Data |
|
|
|
|
|
|
|
| |
| 1. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| APPROXIMATE | Ambient |
|
| Water Temp. (°F) |
| |||
| ICE PRODUCTION | Temp. (°F) |
| 50 |
| 70 |
|
| 90 |
| PER 24 HR. | 70 | *535 | (243) | 510 | (231) |
| 485 | (220) |
|
| 80 | 461 | (209) | 438 | (199) |
| 416 | (189) |
|
| 90 | 396 | (179) | *385 | (175) |
| 358 | (162) |
| lbs./day ( kg/day) | 100 | 340 | (154) | 323 | (147) |
| *304 | (138) |
| APPROXIMATE ELECTRIC | 70 | *985 | 995 |
| 1005 | |||
| CONSUMPTION | 80 | 1015 | 1025 |
| 1035 | |||
|
| 90 | 1045 | *1055 |
| 1056 | |||
| watts | 100 | 1058 | 1059 |
| *1060 | |||
| APPROXIMATE WATER | 70 | *64 | (243) | 61 | (231) |
| 58 | (220) |
| CONSUMPTION PER 24 HR. | 80 | 55 | (209) | 53 | (199) |
| 50 | (189) |
|
| 90 | 48 | (179) | *46 | (175) |
| 43 | (162) |
| gal. / day (l/day) | 100 | 41 | (154) | 39 | (147) |
| *37 | (138) |
| EVAPORATOR OUTLET TEMP. | 70 | *23 | 23 |
| 23 | |||
| °F (°C) | 80 | 23 | 26 |
| 26 | |||
|
| 90 | 26 | *26 |
| 28 | |||
|
| 100 | 28 | 28 |
| *28 | |||
| HEAD PRESSURE | 70 | *230 | (16.2) | 230 | (16.2) |
| 230 | (16.2) |
|
| 80 | 264 | (18.5) | 264 | (18.5) |
| 264 | (18.5) |
| PSIG (kg/cm2G) | 90 | 297 | (20.9) | *297 | (20.9) |
| 297 | (20.9) |
| 100 | 335 | (23.5) | 335 | (23.5) |
| *335 | (23.5) | |
| SUCTION PRESSURE | 70 | *33 | (2.3) | 33 | (2.3) |
| 33 | (2.3) |
| PSIG (kg/cm2G) | 80 | 35 | (2.5) | 35 | (2.5) |
| 35 | (2.5) |
|
| 90 | 37 | (2.6) | *37 | (2.6) |
| 37 | (2.6) |
|
| 100 | 43 | (3.0) | 43 | (3.0) |
| *43 | (3.0) |
| TOTAL HEAT OF REJECTION |
| 6300 BTU/h (AT | 90°F /WT 70°F) |
|
|
Note:
1.The data without *marks should be used for reference only.
2.We reserve the right to make changes in specifications and design without prior notice.
34