Hoshizaki KMS-1400MLH instruction manual Checks Before Installation

Page 11

B. Checks Before Installation

IMPORTANT

1.Install in accordance with all applicable national, state, and local regulations.

2.Remove the shipping carton, tape, and packing material. If any are left in the icemaker or condensing unit, it will not work properly.

3.Ensure all components, fasteners, and thumbscrews are securely in place after installation.

1.Icemaker

1)Remove the panels to prevent damage when installing the icemaker. (See "II.C. How to Remove Panels.")

2)Remove the package containing the accessories.

3)Remove the protective plastic film from the panels. If the icemaker is exposed to the sun or to heat, remove the film after the icemaker cools.

4)Check that the refrigerant lines do not rub or touch lines or other surfaces.

5)This icemaker can be installed on dispenser units or storage bins 30" wide or wider. If using a storage bin, the recommended storage bin is HOSHIZAKI ICE STORAGE BIN, Model B-500 series. For more options, contact your local Hoshizaki distributor.

6)This icemaker is designed for connection to HOSHIZAKI CONDENSING UNIT, Model SRK14H or SRK14H3 only!

NOTE: CONNECTION TO ANOTHER CONDENSING UNIT WILL VOID WARRANTY.

2.Condensing Unit

1)See the nameplate on the condensing unit. Check that your voltage supplied corresponds with the voltage specified on the nameplate.

WARNING

Electrical connections must be installed in accordance with applicable national, state, and local regulations.

2)Remove the panels to prevent damage when installing the condensing unit (See "II.C. How to Remove Panels.")

3)Remove the package containing the accessories from the condensing unit.

4)Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the fan blade turns freely.

5)Check that the compressor is snug on all mounting pads.

11

Image 11
Contents KMS-1400MLH Hoshizaki AMERICA, INC Contents KMS-1400MLH Specifications Nameplate RatingFor Outdoor USE MOTOR-COMPRESSOR Thermally Protected Condensing Unit Model SRK-14HCondensing Unit Model SRK-14H3 Intentionally Left BlankDimensions/Connections Condensing Unit Model SRK-14H/3 Icemaker II. Installation and Operating InstructionsLocation Icemaker Hoshizaki Condensing Unit Condensing UnitChecks Before Installation How to Remove Panels Bin Control Installation Installation of the IcemakerSetup Pump Drain Suction Pipe Hose Thumbscrews Slots Line Set Installation of the Condensing UnitField Fabricated Line Set Installation Factory Line Set InstallationElectrical Connection Electrical Connection Wire Harness Connections Icemaker Water Supply and Drain Connections See FigFinal Checklist Startup Cleaning Procedure III. Cleaning and MaintenanceCleaning and Sanitizing Instructions Page Dispenser Unit/Storage Bin and Scoop MaintenanceSanitizing Procedure Following Cleaning Procedure Stainless Steel ExteriorRemove the water from the potable water supply line See Fig Preparing the Icemaker for Long StoragePage Hoshizaki AMERICA, INC