Hoshizaki KMS-1400MLH instruction manual Water Supply and Drain Connections See Fig, Icemaker

Page 21

G. Water Supply and Drain Connections

See Fig. 9

IMPORTANT

To prevent damage to the equipment, do not operate the icemaker when the water supply is off, or if the pressure is below 10 PSIG. Do not run the icemaker until the proper water pressure is reached.

The icemaker must be installed in accordance with applicable national, state, and local regulations.

A plumbing permit and services of a licensed plumber may be required in some areas.

Water supply inlet is 1/2" female pipe thread (FPT).

A water supply line shut-off valve and drain valve should be installed. A minimum of 1/2" OD copper tubing is recommended for the water supply lines.

Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.

The minimum recommended drain line is 3/4" OD hard pipe.

Icemaker drain outlet is 3/4" FPT. Condensation drain outlet is a 5/8" OD stainless tube. The icemaker and condensate drain line(s) must be run separately from the dispenser unit/storage bin unit drain line.

Drain lines must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get good flow. A vented tee connection is required for proper flow.

Drains should not be piped directly to the sewer system. An air gap of a minimum of

2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker, the condensation drain, the dispenser unit/storage bin and the floor drain. See Fig. 9.

Water Supply Inlet 1/2" FPT

Water Supply Line

KMS-1400MLH

Shut-Off Valve

 

Icemaker

Icemaker Drain Outlet 3/4" FPT

Storage

Bin

 

Water Supply Line Drain Valve

Bin Drain Outlet 3/4" FPT

Separate piping to approved drain. Leave a two-inch (5 cm) vertical air gap between the end of each pipe and the drain.

Two Inch

(5 cm) Air Gap

Condensation Drain 5/8" OD Stainless Tube

Floor

Drain

Fig. 9

21

Image 21
Contents KMS-1400MLH Hoshizaki AMERICA, INC Contents KMS-1400MLH Specifications Nameplate RatingFor Outdoor USE MOTOR-COMPRESSOR Thermally Protected Condensing Unit Model SRK-14HCondensing Unit Model SRK-14H3 Intentionally Left BlankDimensions/Connections Condensing Unit Model SRK-14H/3 II. Installation and Operating Instructions LocationIcemaker Icemaker Hoshizaki Condensing Unit Condensing UnitChecks Before Installation How to Remove Panels Installation of the Icemaker SetupBin Control Installation Pump Drain Suction Pipe Hose Thumbscrews Slots Line Set Installation of the Condensing UnitField Fabricated Line Set Installation Factory Line Set InstallationElectrical Connection Electrical Connection Wire Harness Connections Icemaker Water Supply and Drain Connections See FigFinal Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Page Sanitizing Procedure Following Cleaning Procedure MaintenanceStainless Steel Exterior Dispenser Unit/Storage Bin and ScoopRemove the water from the potable water supply line See Fig Preparing the Icemaker for Long StoragePage Hoshizaki AMERICA, INC