H. Final Checklist

1)Is the icemaker level?

2)Are all components, fasteners, and thumbscrews securely in place?

3)Is there at least 24" (61 cm) minimum clearance around the condensing unit?

4)Have the shipping carton, tape, and packing material been removed from the icemaker and condensing unit? Are the cube guides and tank separator in their correct positions?

5)Is the icemaker in a site where the ambient temperature is within +45°F to +100°F (7°C to 38°C) all year around?

6)Have all electrical, water, and refrigerant connections been made? Are line sets tightened, secured, and free of kinks?

7)Does the electrical installation meet all national, state, and local codes and regulations? Has the power supply voltage been checked or tested against the nameplate rating? Has a proper ground been installed to the condensing unit and icemaker unit? On three phase model, has the transformer's voltage tap switch been positioned to match incoming voltage? For details, see section "II.F. Electrical Connection."

8)Has the electrical power supply been on to the condensing unit for a minimum of

4 hours?

9)Are the water supply line shut-off valve and drain valve installed? Has the water supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of 113 PSIG?

Note: The icemaker may stop running when the water supply is off, or if the pressure is below 10 PSIG.

10)Are the compressor hold-down bolts snug? Have the refrigerant lines been checked to make sure they do not rub or touch other lines or surfaces?

11)Has the bin control been installed and checked for correct operation? To confirm bin control operation, press the bin control's actuator paddle during the first 5 minutes of the freeze cycle. The icemaker should stop within 15 seconds.

12)Were all tank hoses and thumbscrews reconnected and secured after installing the bin control?

Note: Confirm that there is no gap behind the bin control bracket.

13)Has the end user been given the instruction manual, and instructed on how to operate the icemaker and the importance of the recommended periodic maintenance?

14)Has the end user been given the name and telephone number of an authorized service agent?

15)Has the warranty card been filled out and forwarded to the factory for warranty registration?

22

Image 22
Contents KMS-1400MLH Hoshizaki AMERICA, INC Contents Specifications Nameplate Rating KMS-1400MLHCondensing Unit Model SRK-14H For Outdoor USE MOTOR-COMPRESSOR Thermally ProtectedIntentionally Left Blank Condensing Unit Model SRK-14H3Dimensions/Connections Condensing Unit Model SRK-14H/3 Location II. Installation and Operating InstructionsIcemaker Condensing Unit Icemaker Hoshizaki Condensing UnitChecks Before Installation How to Remove Panels Setup Installation of the IcemakerBin Control Installation Pump Drain Suction Pipe Hose Thumbscrews Slots Installation of the Condensing Unit Line SetFactory Line Set Installation Field Fabricated Line Set InstallationElectrical Connection Electrical Connection Wire Harness Connections Water Supply and Drain Connections See Fig IcemakerFinal Checklist Startup Cleaning and Sanitizing Instructions III. Cleaning and MaintenanceCleaning Procedure Page Stainless Steel Exterior MaintenanceSanitizing Procedure Following Cleaning Procedure Dispenser Unit/Storage Bin and ScoopPreparing the Icemaker for Long Storage Remove the water from the potable water supply line See FigPage Hoshizaki AMERICA, INC