e. Reassemble the float switch. Replace the rubber boot and the float switch in their correct positions. Reconnect the vent tube.

f. Replace the right-side panel in its correct position.

9)Remove the insulation panel by removing the thumbscrews, then pour the cleaning solution into the water tank.

10)Move the service switch to the "WASH" position.

11)Replace the insulation panel and the front panel in their correct positions.

12)Turn on the power supply to start the washing process.

13)Turn off the power supply after 30 minutes. Remove the front panel.

14)Move the service switch to the "DRAIN" position.

15)Replace the front panel and turn on the power supply for 2 minutes.

16)Turn off the power supply and remove the front panel.

17)Move the control switch to the "ICE" position.

18)Replace the front panel in its correct position.

19)Turn on the power supply to fill the water tank with water.

20)Turn off the power supply after 3 minutes.

21)Remove the front panel.

22)Move the control switch to the "SERVICE" position, then move the service switch to the "WASH" position.

23)Replace the front panel in its correct position.

24)Turn on the power supply to rinse off the cleaning solution.

25)Turn off the power supply after 5 minutes.

26)Remove the front panel.

27)Move the service switch to the "DRAIN" position.

28)Replace the front panel and turn on the power supply for 2 minutes.

29)Turn off the power supply. Remove the front panel.

30)Repeat steps 17 through 29 three more times to rinse thoroughly.

Note: If you do not sanitize the icemaker, go to step 13 in "2. Sanitizing Procedure."

25

Image 25
Contents KMS-1400MLH Hoshizaki AMERICA, INC Contents KMS-1400MLH Specifications Nameplate RatingFor Outdoor USE MOTOR-COMPRESSOR Thermally Protected Condensing Unit Model SRK-14HCondensing Unit Model SRK-14H3 Intentionally Left BlankDimensions/Connections Condensing Unit Model SRK-14H/3 Location II. Installation and Operating InstructionsIcemaker Icemaker Hoshizaki Condensing Unit Condensing UnitChecks Before Installation How to Remove Panels Setup Installation of the IcemakerBin Control Installation Pump Drain Suction Pipe Hose Thumbscrews Slots Line Set Installation of the Condensing UnitField Fabricated Line Set Installation Factory Line Set InstallationElectrical Connection Electrical Connection Wire Harness Connections Icemaker Water Supply and Drain Connections See FigFinal Checklist Startup Cleaning and Sanitizing Instructions III. Cleaning and MaintenanceCleaning Procedure Page Sanitizing Procedure Following Cleaning Procedure MaintenanceStainless Steel Exterior Dispenser Unit/Storage Bin and ScoopRemove the water from the potable water supply line See Fig Preparing the Icemaker for Long StoragePage Hoshizaki AMERICA, INC