E. Electrical Connection

WARNING

1.Electrical connection must be made in accordance with the instructions on the "WARNING" tag, provided with the pig tail leads in the junction box.

2.Electrical connections must meet national, state, and local electrical code requirements. Failure to meet these code requirements could cause severe injury to individuals or extensive damage to equipment.

3.Be sure to install a proper ground to the icemaker.

Electrical connections must be installed in accordance with applicable national, state, and local regulations.

The icemaker requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size.

The maximum allowable voltage variation is ±10 percent of the nameplate rating.

The white lead must be connected to the neutral conductor of the power source. Miswiring results in severe damage to the icemaker. See Fig. 3.

The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

Usually an electrical permit and services of a licensed electrician are required.

WARNING

ELECTRICAL CONNECTION

The white lead must be connected to the neutral conductor of

the power source. Miswiring results in severe damage to the icemaker. (See Fig. below.)

Fig. 3

12

Image 12
Contents KMD-901MAH KMD-901MWH KMD-901MRH Hoshizaki AMERICA, INC Contents Specifications Nameplate Rating KMD-901MAH air-cooledKMD-901MWH water-cooled KMD-901MRH remote air-cooled Dimensions / Connections KMD-901MAHKMD-901MWH KMD-901MRH How to Remove Panels See FigSetup LocationElectrical Connection Electrical ConnectionInstallation of Remote Condenser Unit Checks Before InstallationLocation Setup Line SetFactory Line Set Installation Field Fabricated Line Set InstallationElectrical Connection Stacking Remote Condenser UnitWater Supply and Drain Connections With Storage Bin KMD-901MRHFinal Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Stainless Steel ExteriorStorage Bin and Scoop Preparing the Icemaker for Long Storage Air Filters air-cooled model onlyCondenser air-cooled and remote air-cooled models only Remove the water from the icemaker water supply lineDrain the water tank Hoshizaki AMERICA, INC