II.Installation and Operating Instructions A. Checks Before Installation

IMPORTANT

1.Install in accordance with all applicable national, state, and local regulations.

2.Remove the shipping carton, tape, and packing material. If any are left in the icemaker, it will not work properly.

3.Ensure all components, fasteners, and thumbscrews are securely in place after installation.

1)Remove the panels to prevent damage when installing the icemaker. (See "B. How to Remove Panels.")

2)Remove the package containing the accessories.

3)Remove the protective plastic film from the panels. If the icemaker is exposed to the sun or to heat, remove the film after the icemaker cools.

4)Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the fan blade turns freely.

5)Check that the compressor is snug on all mounting pads.

6)See the nameplate on the rear panel, and check that your voltage supplied corresponds with the voltage specified on the nameplate.

7)This icemaker can be installed on a storage bin or dispenser unit. The KMD-901MAH requires a storage bin or dispenser unit 42" wide or wider. The KMD-901MWH and KMD-901MRH require a storage bin or dispenser unit 30" wide or wider. If using a storage bin with a KMD-901MAH, the recommended bin is HOSHIZAKI ICE STORAGE BIN, Model B-700 series. With a KMD-901MWH or KMD-901MRH, the recommended bin is HOSHIZAKI ICE STORAGE BIN, Model B-500 series.

8)On remote air-cooled models, a remote condenser unit is needed. The recommended remote condenser unit is HOSHIZAKI REMOTE CONDENSER UNIT, Model URC-9F.

B. How to Remove Panels

See Fig. 1

Front Panel: Remove the screw. Lift up and towards you.

Top Panel: Lift up at front slightly, push rearward, and lift off.

Side Panel (R): Remove the screw. Slide forward slightly, and lift off.

Insulation Panel: Remove thumbscrew, lift up slightly, and pull towards you.

Top Panel

Side

Panel (R)

 

Insulation

Panel

Front

Panel

Fig. 1

10

Image 10
Contents KMD-901MAH KMD-901MWH KMD-901MRH Hoshizaki AMERICA, INC Contents Specifications Nameplate Rating KMD-901MAH air-cooledKMD-901MWH water-cooled KMD-901MRH remote air-cooled Dimensions / Connections KMD-901MAHKMD-901MWH KMD-901MRH How to Remove Panels See FigSetup LocationElectrical Connection Electrical ConnectionChecks Before Installation Installation of Remote Condenser UnitLocation Setup Line SetFactory Line Set Installation Field Fabricated Line Set InstallationElectrical Connection Stacking Remote Condenser UnitWater Supply and Drain Connections With Storage Bin KMD-901MRHFinal Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Stainless Steel Exterior MaintenanceStorage Bin and Scoop Condenser air-cooled and remote air-cooled models only Preparing the Icemaker for Long StorageAir Filters air-cooled model only Remove the water from the icemaker water supply lineDrain the water tank Hoshizaki AMERICA, INC