G. Water Supply and Drain Connections
See Fig. 9
CAUTION
To prevent damage to equipment, do not operate the icemaker when the water supply is off, or if the pressure is below 10 PSIG. Do not run the icemaker until the proper water pressure is reached.
• Water supply inlet is 1/2" female pipe thread (FPT).
Note: On
•A water supply line
•Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
•The minimum recommended drain line is 3/4" OD hard pipe.
•Icemaker drain outlet is 3/4" FPT. Condensation drain outlet is a 5/8" OD stainless tube. The icemaker and condensation drain line(s) must be run separately from the storage bin/dispenser unit drain line.
Note:
•Drain lines must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get good flow. A vented tee connection is also required for proper flow.
•Drain lines should not be piped directly to the sewer system. An air gap of a minimum of 2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker, the condensation drain, the storage bin/dispenser unit, and the
•This icemaker must be installed in accordance with applicable national, state, and local regulations.
•A plumbing permit and services of a licensed plumber may be required in some areas.
•
17