Hoshizaki KMD-901MRH, KMD-901MAH, KMD-901MWH Electrical Connection, Stacking Remote Condenser Unit

Page 16

5. Electrical Connection

WARNING

1.Electrical connections must meet national, state, and local electrical code requirements. Failure to meet these code requirements could cause severe injury to individuals or extensive damage to equipment.

2.Be sure to install a proper ground from the icemaker to the remote condenser unit.

This remote condenser unit must be connected to the fan motor junction box on the icemaker.

The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

Usually an electrical permit and services of a licensed electrician are required.

1)Remove the louver panel.

2)Remove the junction box cover on the remote condenser unit. Remove the fan motor junction box cover on the icemaker.

3)Install a ground wire from the icemaker to the remote condenser unit.

4)Connect the fan motor leads in the junction box of the remote condenser unit to the fan motor leads in the fan motor junction box of the icemaker.

5)Replace the junction box covers and the louver panel in their correct positions.

6.Stacking Remote Condenser Unit

1)Secure the lower remote condenser unit to the legs with eight bolts (not included).

2)Attach the upper remote condenser unit on the top of the lower.

3)Secure the upper remote condenser unit with the four screws provided.

4)Install refrigerant lines, and make electrical connection for each fan motor as shown earlier in this section.

Screw

Upper Remote

 

Condenser Unit

Screw

Screw

 

Lower Remote

Condenser Unit

Junction Box Cover

Louver Panel

Fig. 7

Fig. 8

16

Image 16
Contents KMD-901MAH KMD-901MWH KMD-901MRH Hoshizaki AMERICA, INC Contents Specifications Nameplate Rating KMD-901MAH air-cooledKMD-901MWH water-cooled KMD-901MRH remote air-cooled Dimensions / Connections KMD-901MAHKMD-901MWH KMD-901MRH How to Remove Panels See FigSetup LocationElectrical Connection Electrical ConnectionChecks Before Installation Installation of Remote Condenser UnitLocation Setup Line SetFactory Line Set Installation Field Fabricated Line Set InstallationElectrical Connection Stacking Remote Condenser UnitWater Supply and Drain Connections With Storage Bin KMD-901MRHFinal Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Stainless Steel Exterior MaintenanceStorage Bin and Scoop Preparing the Icemaker for Long Storage Air Filters air-cooled model onlyCondenser air-cooled and remote air-cooled models only Remove the water from the icemaker water supply lineDrain the water tank Hoshizaki AMERICA, INC