Hoshizaki KMD-901MWH, KMD-901MAH, KMD-901MRH instruction manual Location, Setup

Page 11

C. Location

CAUTION

1.This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within +45°F to +100°F (+7°C to +38°C); Normal operating water temperature should be within +45°F to +90°F (+7°C to +32°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect icemaker performance.

2.This icemaker will not work at sub-freezing temperatures. To prevent damage to the water supply line, drain the icemaker if the air temperature is going to go below 32°F (0°C). See "III.C. Preparing the Icemaker for Long Storage."

For best operating results:

Icemaker should not be located next to ovens, grills, or other high heat producing equipment.

Avoid choosing a site where no dripping is allowed.

Allow 6" (15 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required.

Location should provide a firm and level foundation for the equipment.

D.Setup

1)If mounting the unit on top of a storage bin, unpack the storage bin, and attach the four adjustable legs provided (bin accessory) to the bottom of the storage bin. If mounting the unit on top of a dispenser, follow the dispenser's setup procedure.

2)Position the storage bin/dispenser unit in the selected permanent location.

3)Place the icemaker on top of the storage bin/dispenser unit.

4)Secure the icemaker to the storage bin/dispenser unit using the two mounting brackets and the bolts provided. See Fig. 2.

5)Level the icemaker and storage bin/dispenser unit in both the left-to-right and front-to- rear directions. If using a storage bin, adjust the storage bin legs to make the icemaker level.

6)Replace the panels in their correct positions.

Icemaker

 

 

Icemaker

Mounting

 

 

Mounting

Bracket

 

 

Bracket

Bolt

 

 

Bolt

Bin

Fig. 2

Dispenser

11

Image 11
Contents KMD-901MAH KMD-901MWH KMD-901MRH Hoshizaki AMERICA, INC Contents KMD-901MAH air-cooled Specifications Nameplate RatingKMD-901MWH water-cooled KMD-901MRH remote air-cooled KMD-901MAH Dimensions / ConnectionsKMD-901MWH KMD-901MRH See Fig How to Remove PanelsLocation SetupElectrical Connection Electrical ConnectionLocation Installation of Remote Condenser UnitChecks Before Installation Line Set SetupField Fabricated Line Set Installation Factory Line Set InstallationStacking Remote Condenser Unit Electrical ConnectionWater Supply and Drain Connections KMD-901MRH With Storage BinFinal Checklist Startup Cleaning and Sanitizing Instructions III. Cleaning and MaintenanceCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Storage Bin and Scoop MaintenanceStainless Steel Exterior Remove the water from the icemaker water supply line Preparing the Icemaker for Long StorageAir Filters air-cooled model only Condenser air-cooled and remote air-cooled models onlyDrain the water tank Hoshizaki AMERICA, INC