Hoshizaki KMD-901MRH, KMD-901MAH, KMD-901MWH instruction manual Cleaning Procedure

Page 22

1.Cleaning Procedure

1)Dilute 13.5 fl. oz. (400 ml) of recommended cleaner Hoshizaki "Scale Away" or "LIME- A-WAY," (Economics Laboratory, Inc.) with 2.5 gal. (9.5 l) of warm water.

2)Remove all ice from the evaporator and the storage bin.

Note: To remove cubes on the evaporator, turn off the power supply and turn it back on after 3 minutes. The harvest cycle starts and the cubes will be removed from the evaporator.

3)Turn off the power supply.

4)Remove the front panel. Remove the insulation panel. Remove cube guide B, then remove cube guide A. Remove the overflow cap, overflow pipe, and water shield. See Fig. 11.

5)Remove the drain plug and drain the water tank. Replace the drain plug in its correct position. Be careful not to cross thread it.

6)Replace the water shield, overflow pipe, overflow cap, cube guide A, and cube guide B in their correct positions. Be careful not to cross thread the overflow pipe.

7)In bad or severe water conditions, clean the float switch as described below. Otherwise, continue to step 8.

a.Disconnect the vent tube and flush tube from the top of the float switch, then remove the float switch and rubber boot.

b.Remove the retainer rod from the bottom of the float switch assembly, then remove the float. Be careful not to bend the retainer rod excessively when removing it.

c.Wipe down the float switch assembly's housing, shaft, float, and retainer rod with cleaning solution. Clean the inside of the rubber boot and hose with cleaning solution. Rinse the parts thoroughly with clean water.

d.Reassemble the float switch assembly and replace it and the rubber boot in their correct positions. Reconnect the vent tube and the flush tube.

8)Pour the cleaning solution into the water tank.

 

Overflow Cap

Fig. 11

Overflow Pipe

 

Water Shield

Drain Plug

Cube Guide A

Cube Guide B

 

22

Image 22
Contents KMD-901MAH KMD-901MWH KMD-901MRH Hoshizaki AMERICA, INC Contents Specifications Nameplate Rating KMD-901MAH air-cooledKMD-901MWH water-cooled KMD-901MRH remote air-cooled Dimensions / Connections KMD-901MAHKMD-901MWH KMD-901MRH How to Remove Panels See FigSetup LocationElectrical Connection Electrical ConnectionChecks Before Installation Installation of Remote Condenser UnitLocation Setup Line SetFactory Line Set Installation Field Fabricated Line Set InstallationElectrical Connection Stacking Remote Condenser UnitWater Supply and Drain Connections With Storage Bin KMD-901MRHFinal Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Stainless Steel Exterior MaintenanceStorage Bin and Scoop Condenser air-cooled and remote air-cooled models only Preparing the Icemaker for Long StorageAir Filters air-cooled model only Remove the water from the icemaker water supply lineDrain the water tank Hoshizaki AMERICA, INC