Hoshizaki KM-1300MRH, KM-1300MWH, KM-1300MAH service manual Controller Board

Page 38

PROBLEM

POSSIBLE CAUSE

 

REMEDY

 

 

 

 

 

 

 

 

 

 

 

l) Controller Board

1.

Defective

1.

See "II.2[e] CHECKING

 

 

 

 

 

 

 

 

CONTROLLER BOARD."

 

 

m) Interlock Switch

1.

“OFF” position.

1.

Move to “ON” position.

 

 

(Cleaning Valve)

 

2.

Bad contacts.

2.

Check for continuity and

 

 

 

 

 

 

 

 

replace.

[2] Water

a) Float switch

1.

Connector disconnected.

1.

Place in position.

continues to

 

 

 

2.

Leads opened or defective

2.

Check and replace.

be supplied,

 

 

 

 

switch.

 

 

and the ice-

 

 

3.

Float does not move freely.

3.

Clean or replace.

maker will not

b) Controller Board

1.

Defective.

1.

Replace.

start.

 

 

 

 

 

 

 

[3] Compressor

a) Wash Switch

1.

“WASH” position.

1.

Move to “ICE” position.

 

 

 

 

2.

Bad contacts.

2.

Check and replace.

 

 

b) High Pressure

1.

Dirty Air Filter or

1.

Clean.

 

 

Controller

 

 

Condenser.

 

 

 

 

 

 

 

2. Ambient or condenser

2. Reduce ambient temp.

 

 

 

 

 

 

water temp. too warm.

 

 

 

 

 

 

 

3. Refrigerant overcharged.

3.

Recharge.

 

 

 

 

 

4. Condenser water pressure

4.

Check and get

 

 

 

 

 

 

too low or off. [Water-

 

recommended pressure.

 

 

 

 

 

 

cooled model only].

 

 

 

 

 

 

5.

Fan not operating. [Except

5.

See chart 1 - [6].

 

 

 

 

 

 

water-cooled model].

 

 

 

 

 

 

6.

Refrigerant line or

6.

Clean and replace Drier.

 

 

 

 

 

 

components plugged.

 

 

 

 

c) Water Regulator

1.

Set too high.

1.

Adjust lower.

 

 

d) Overload Protector

1.

Bad contacts.

1.

Check for continuity and

 

 

 

 

 

 

 

 

replace.

 

 

 

 

2.

Voltage too low.

2.

Increase voltage.

 

 

 

 

3.

Refrigerant overcharged or

3. Recharge.

 

 

 

 

 

 

undercharged.

 

 

 

 

 

 

4.

Line Valve continues to

4.

Check Line Valve’s

 

 

 

 

 

 

close in freeze cycle and

 

operation in freeze cycle

 

 

 

 

 

 

Overload Protector

 

and replace.

 

 

 

 

 

 

operates.

 

 

 

 

e) Starter

1.

Bad contacts.

1.

Check and replace.

 

 

 

 

2.

Coil winding opened.

2.

Replace.

 

 

f) Start Capacitor or

1.

Defective.

1.

Replace.

 

 

Run Capacitor

 

 

 

 

 

 

 

g) Magnetic Contactor

1.

Bad contacts.

1.

Check for continuity and

 

 

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

 

 

 

 

2.

Coil winding opened.

2.

Replace.

 

 

h) Compressor

1.

Wiring to Compressor.

1.

Check for loose

 

 

 

 

 

 

 

 

connection or open, and

 

 

 

 

 

 

 

 

replace.

 

 

 

 

2.

Defective.

2.

Replace.

 

 

 

 

3.

Protector tripped.

3.

Reduce temperature.

 

 

i) Controller board

1.

Defective.

1.

See “II.2. [e] CHECKING

 

 

 

 

 

 

 

 

CONTROLLER BOARD.”

[4] Water

a) Water Solenoid

1.

Diaphragm does not close.

1.

Check for water leaks

continues to

Valve

 

 

 

 

with icemaker off.

be supplied in

b) Controller Board

1.

Defective.

1.

See “II.2.[e] CHECKING

freeze cycle.

 

 

 

 

 

 

CONTROLLER BOARD.”

 

 

 

 

 

 

 

 

 

38

Image 38
Contents KM-1300MAH KM-1300MWH KM-1300MRH Hoshizaki AMERICA, INC Contents Maintenance Specifications KM-1300MAH Air-cooled2a. KM-1300MWH Water-cooled 2b. KM-1300MWH Water-cooled Serial No. M10156D KM-1300MRH Remote air-cooled Condensing Unit URC-12F Specifications Model URC-12F II. General Information Construction KM-1300MWH Water-cooled KM-1300MRH Remote air-cooled SOLID-STATE Control Features of Control Products E Controller BoardController Board Controller BoardPage Harvest Cycle Beep every 3 sec. = High Evaporator Temperature 127 FMinute Fill Cycle Freeze CycleControl Products HOS-001A Board Sequence 1st Cycle 2nd Cycle and after with pump drain 2nd Cycle and after with no pump drain Controls and Adjustments Setting Time Setting Frequency Checking the Controller Board Page III. Technical Information KM-1300MWH Water-cooled KM-1300MRH Remote air-cooled Wiring Diagrams KM-1300MAH Air-cooled and KM-1300MWH Water-cooledCut-out 412 ±21.3 Psig Cut-in 327±21.3 Psig Timing Chart Page Performance Data Serial # L00001F to M10155C KM-1300MWH Water-cooled Serial # M10156D KM-1300MRH Remote air-cooled IV. Service Diagnosis No ICE Production Problem Possible Cause RemedyController Board Problem Possible Cause Remedy Evaporator is Frozen UP LOW ICE ProductionAbnormal ICE OthersEvacuation and Recharge R-404A Service for Refrigerant LinesRefrigerant Recovery Brazing Removal and Replacement of Compressor Important Removal and Replacement of Drier Removal and Replacement of Expansion Valve Removal and Replacement of HOT GAS Valve and Line Valve Removal and Replacement of Evaporator Important Page Page Page Removal and Replacement of Thermistor Important Removal and Replacement of FAN Motor Removal and Replacement of Water Valve Removal and Replacement of Pump MotorRemoval and Replacement of Spray Tubes VI. Maintenance and Cleaning Instructions Preparing the Icemaker for Long StoragePage Cleaning Cleaning Procedure Sanitizing Procedure Following Cleaning Procedure Page Maintenance