Installation
NOTE: Be careful not to cut or nick copper strands. If more than five strands are cut or nicked, trim wire and
New hoses are
a.Ensure strip length is correct by fitting ferrule over exposed wire. Ferrule should be flush with wire end. See FIG. 7.
NOTE: On some older heated hoses wire insulation will not fit inside ferrule insulator. In these cases, use scissors to split and remove ferrule insulator.
b.If wire is short of ferrule end, adjust strip length accordingly. If bare wire is protruding from fer- rule, trim flush to ferrule end. See FIG. 7.
Incorrect
Correct
Incorrect
TI9768a
FIG. 7
c.Remove ferrule and apply oxide inhibitor to bare wire. See FIG. 8.
d.Reinsert wire in ferrule and apply more oxide inhibitor to ferrule and wire end.
TI9769A
FIG. 8
6.Pair electrical wires as follows:
NOTE: When connecting first hose section to pro- portioner, wire pairing does not make a difference.
a.Insert one wire from heated hose into connec- tor. Ensure that ferrule is mating with connector insert. See FIG. 9.
TI9770A
FIG. 9: Insert Wire and Setscrew
b.Thread in setscrew and use hex wrench to torque setscrew to 60
NOTE: To reach approximately 60
TI9779A
FIG. 10: Torque Setscrew
c.Insert remaining wire from pair into connector; ensure proper insertion depth. Thread setscrew and torque to 60
d.Repeat
e.
NOTE: When torqued to 60
18 | 3A0237L |