Graco 3A0237L important safety instructions Operation, Single Heat Zone Shown

Page 23

Operation

Do not operate a coiled hose. A coiled hose creates uneven heat buildup which can result in hose rupture and cause serious injury, including fluid injection.

Maximum hose operating temperature is 180°F (82°C). If using hose without an FTS, measure hose temperature to ensure it does not exceed 180°F (82°C).

Hose must be properly supported to avoid excessive strain due to weight, bending, or sharp edges.

Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury.

Open a valve to relieve the fluid expansion during heating.

Replace hoses proactively at regular intervals based on your operating conditions.

1.Connect air hose (C) to main air supply if equipped.

2.Connect electrical connectors (D) to connector from fluid manifold (M) or accessory control box. See , page 16. Connect hose cable (F) to cable from pro- portioner fluid manifold (M) or accessory control box. Connect signal cable (24) to connector behind the proportioner fluid manifold (M).Wrap connec- tions with electrical tape.

Single Heat Zone Shown

M

13

F

C

M

FIG. 20

Operation

D

TI14737b

(24) connector

3A0237L

23

Image 23
Contents Heated Hoses Applicator Kits Important Safety InstructionsRelated Manuals ContentsCarbon Steel Dual Heat Zone Hose Bundle with Air Hose Heated Hose Bundle Part NumbersFittings Fluid Temperature Sensor FTSHeated Whip Hose Side Heated Hoses Red Individual HosesIndividual a Side Heated Whip Hose Side Unheated Hoses RedSide Heated Hoses Blue Individual B Side Heated Whip Hose Side Unheated Hoses BlueApplicator Kits See manual MD2 Valve Applicator KitsMD2 Handle Chemical Connection Kit Electric Shock Hazard Toxic Fluid or Fumes Hazard Personal Protective Equipment Important Two-Component Material Information Changing Materials B ComponentsConnect Whip Hose to Gun or Gun Manifold InstallationDescription Single Heat Zone with a or B Heated Hose Connect Heated HosesSingle Heat Zone with a and B Heated Hose Dual Heat Zone with a and B Heated HoseIncorrect Correct Insert Wire and SetscrewSee Connect FTS and Heated Whip Hose, Cap plugs SetscrewsConnect FTS and Heated Whip Hose Connect Splitter Connect Solenoid KitProtective Covering Check Hoses for LeaksSingle Heat Zone Shown OperationInstructions for Replacing Individual a or B Hose MaintenanceClean Orifice Follow Pressure Relief Procedure in MD2 valve manualMaintenance 3A0237L For Single Zone Heated Whip Hose Bundles Bundle Individual Whip HosesSide Dual Heat Zone Heated Whip Hose BundleSingle Heat Zone Heated Whip Hose Bundle Bundle Individual Heated Hoses Machine End Dual Heat Zone Heated Hose Bundle ShownSingle Heat Zone Heated Whip Hose PartsWhip Hoses Dual Heat Zone Heated Whip HoseHeated Whip Hoses Heated Hose Bundles Varied Parts Dual Zone Heated Hose BundlesSingle Zone Heated Hose Bundles Stainless Steel Fluid Temperature Sensor Using Fluid Temperature Sensors For Single Heat ZonesUsing Fluid Temperature Sensors for Dual Heat Zones Carbon Steel Fluid Temperature SensorConnect 258758 , 15F144 Hose Wire JumperPart Description Qty 24E505 Orifice Block Kit MD2 Applicator KitsMD2 Applicator Kits 153 24D162 Stainless Steel Connection Kit24C757 Machine Mount Kit AccessoriesScuff Guard Solenoid KitsOnly 24D160 24D160 Remote Mount MD2 Kit 24D161 Remote Mount Fusion KitOnly 24D161 Category Data Technical DataTechnical Data 3A0237L Graco Information Graco Standard Warranty