Applicator Kits
Applicator Kits
The table below lists applicators that can be used with the heated hoses and identifies which applicators require sole- noid kits. See Related Manuals for the applicator manual numbers.
NOTE: The MD2 valves must use one of the chemical connection kits to connect to the fluid hoses. See MD2 Valve Applicator Kits on page 10.
NOTE: When selecting an applicator, if an applicator is chosen which does not have a signal communicating to the
HFR, then the sizes of the A and B pumps added together must be greater or equal to 120 cc. For example: A (red) pump size = 20 cc, B (blue) pump size = 100 cc, 20 cc + 100 cc = 120 cc. Since the pump sizes combined = 120 cc, an applicator may be selected which does not have a signal communicating to the HFR.
Applicator | Handle Options | Required Solenoid Kit | Pressure Relief Kit |
|
|
|
|
Automatic Fusion Air Purge Guns | No handle | 24D161 |
|
Automatic Fusion Mechanical Purge Guns | No handle | 24D161 |
|
Fusion Air Purge Guns |
|
| 24C067 |
Fusion Mechanical Purge Guns |
|
| 24C067 |
Fusion CS Guns |
|
| 24C067 |
EP Gun | No handle |
|
|
|
|
| |
Electric actuated pistol |
|
| |
|
|
| |
|
|
|
|
1:1 and 10:1 MD2 Valves | No handle | 24D160, 24C757 |
|
Electric actuated pistol | 24D160, 24C757 |
| |
(See MD2 Valve Applicator Kits on page 10 |
| ||
Pneumatic |
|
| |
for models and chemical connection kits) |
|
| |
| Electric actuated lever | 24D160, 24C757 |
|
|
|
|
|
3A0237L | 9 |