SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

UNIVERSAL TIMER PROGRAMMING INSTRUCTIONS

INSTRUCTIONS FOR CHEMICAL FEEDER PUMPS (FOR INSTALLATION TECHNICIAN ONLY)

To access the programming mode, the machine must be ON, and idle (between cycles).

On the timer board, press both the MOVE and ENTER buttons on the timer board simultaneously.

The PROGRAM light will illuminate and the A light will blink.

Once in the programming mode, the MOVE button is used to scroll between the programming categories and the ENTER but- ton is used to select the category.

Press the MOVE button to move the blinking light between FILL, RINSE AID, DETERGENT or SANITIZER.

Press the ENTER button for the chosen category.

The PROGRAM light will illuminate along with the lights corresponding to the time values for the chosen category. The ACCEPT light will blink.

To change the value of a parameter, use the MOVE button to move the blinking light to the time option (time is in seconds). In the time categories, each second in use will light up. To deselect the option, press ENTER and the light will go off, press ENTER again and it will illuminate. Once you have set your time category, press the MOVE button until the ACCEPT light is blinking and press ENTER. This will save the changed parameters.

Once you press the ENTER button when the ACCEPT light is blinking, you will exit the programming mode. To change any other values, you will have to return to the programming mode. To revert back to a previous setting, you must return to that option and change the parameter back to the previous setting.

Once in the programming mode, if there have been no keypad inputs for approximately 2 minutes, the system will automati- cally exit out of the programming mode. Any changes to parameters will be saved when the programming mode is automati- cally exited.

All time adjustments are in seconds. Refer to the chart below for the adjustable outputs.

Please note that options A, B, and D are not adjustable outputs.

Conserver XL Series Technical Manual 7610-002-10-23

Issued: 11-28-2007 Revised: N/A

23

Image 30
Contents INSTALLATION/OPERATION Technical Manual Manufacturers Warranty ONE Year Limited Parts & Labor WarrantyStop Pare Arret Revision Made Applicable Details Date ECN Model Serial No Installation Date Service Rep. Name Phone No Nomenclature for the Models Covered in this ManualTable of Contents Electrical Diagrams Service Repair CentersSection Specification Information Tank Capacity Minimum Specification InformationOperating Cycle Seconds Wash Time Wash Pump CapacityTemperatures Operating Cycle SecondsDimensions Conserver AXL Dimensions Conserver AXL2 Dimensions Conserver AXL2-CML Rdimensions Conserver AXL2-CMR Dimensions Conserver XL Starting with S/N 04D10286 25mmSection Dimensions Conserver XL2-CML Dimensions Conserver XL2-CMR 204 526mm 441 1130mm 481 1232mmXLS Bowl Option Table Dimensions Straight Through InstallationSection INSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions Installation InstructionsElectrical Instructions Priming Chemical Feeder Pumps First-aid instructionsOperation Instructions INSTALLATION/OPERATION Instructions CAM Timer Operation INSTALLATION/OPERATION Instructions Mechanical Timer Timing Sequence Seconds Into Cycle INSTALLATION/OPERATION Instructions Universal Timer Programming Instructions Section Preventative Maintenance Preventative Maintenance Preventative MaintenanceSection Troubleshooting Section Troubleshooting Common Problems Domestic UnitsProblem Machine cycles continuously Problem Machine will not fill, other functions work Problem Wash motor runs continuouslyProblem Machine will not hold water Problem Machine keeps tripping the service breaker Problem Machine runs with door openProblem Low pumped water pressure Problem Machine will not drainProblem Prime switch does not activate sanitizer pump Problem Detergent not feeding rinse aid feeds okayProblem Rinse aid not feeding, detergent feeds okay Common Problems Export Units Problem Machine will not fill, other functions work Problem Machine runs with door open Problem Prime switch does not activate sanitizer pump Section Parts Section Control BOX Assemblies Universal Timer Parts SectionQTY Description Control BOX Assemblies Mechanical Timer Control BOX Assembly with Mechanical Timer XLS Bowl Option Parts Section Timer Motor Mechanical 8 CAM TimerMicroswitch QtyChemical Feeder Pump Assembly 04320-002-82-28Hood Assembly Conserver XL2 Hood Assembly Cantilever ARM Double Bracket Mount Arm, Cantilever, Conserver XL Prior to S/N 04D10286 Conserver XL2 Cantilever ARM Assembly Single Bracket Mount False Panel Weldment Conserver XL2 TUB Assembly Left Front View Conserver XL2 Series TUB Assembly Right Front View Conserver XL2 Series Frame Weldment & Accumulator Plumbing Assembly Incoming Plumbing AssembliesConserver AXL Incoming Coil & Housing only Solenoid Valve & 3/4 NPT Vacuum Breaker Repair Parts KitsComplete 110 Volt Solenoid Valve Assembly Complete 240 Volt Solenoid Valve AssemblyConserver XL Wash Motor Assembly Motor & Pump Assembly Other parts not shownWash Manifold Assembly Drain Solenoid Assembly Miscellaneous Parts CML Assembly Options Represents an item not shown CMR Assembly Options Hood Weldment Conserver XL2-CMR Shown Conserver XL Hood Assembly Prior to S/N 04D10286 Conserver XL Door & Wrap Assemblies Prior to S/N 04D10286 Conserver XL Front DoorLower Frame, Conserver XL False Panel Installation False panel positioned in unitSection Electrical Schematics Electrical Schematics Conserver AXL 115 Volt 60 Hertz Single PhaseConserver AXL2 115 Volt 60 Hertz Single Phase Conserver AXL2-CML/CMR 115 Volt 60 Hertz Single Phase Conserver AXL2-CML/CMR 208-230 Volt 60 Hertz Single Phase Conserver Axls 115 Volt 60 Hertz Single Phase Conserver AXLS2 115 Volt 60 Hertz Single Phase Conserver XL Mechanical Timer 115 Volt 60 Hertz Single Phase Electrical Schematics Electrical Schematics Electrical Schematics Section Jackson Maintenance Repair Centers Jackson Maintenance & Repair Centers Alabama to FloridaService CO Florida to MarylandJackson Service Compa Maryland to NEW YorkCertified Service Center Rons Service NEW York to PennsylvaniaRhode Island to Wisconsin CENTER, INCWisconsin to WYOMING/INTERNATIONAL