SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
MECHANICAL TIMER TIMING SEQUENCE
2 SECONDS INTO CYCLE
*Wash pump starts, runs for 40 seconds, then shuts down. Controlled by C2 cam.
4 SECONDS INTO CYCLE
*Detergent feed pump is energized. The length of time will be field determined. Time will depend on the detergent used and water conditions. Controlled by C6 cam.
10 SECONDS INTO CYCLE
* Detergent feed pump shuts down. Controlled by C6 cam.
42 SECONDS INTO CYCLE
*Wash pump shuts down. Controlled by C2 cam.
*Drain solenoid is energized (opens). Wash water drains from the unit. Controlled by C3 cam.
51 SECONDS INTO CYCLE
* Fill solenoid valve is energized (opened) starting to fill unit. Controlled by C4 cam.
53 SECONDS INTO CYCLE
* Drain solenoid valve is
54 SECONDS INTO CYCLE
*Sanitizer pump is energized, injecting sanitizer into wash tank. Controlled by C5 cam.
*Rinse aid pump is energized, injecting rinse aid into wash tank. Controlled by C7 cam.
58 SECONDS INTO CYCLE
*Sanitizer pump is
60 SECONDS INTO CYCLE
*Rinse aid pump is
62 SECONDS INTO CYCLE
*Wash pump is energized for the rinse cycle.
*Fill solenoid valve is
87 SECONDS INTO CYCLE
*Wash pump is
*End of cycle.
Conserver XL Series Technical Manual
Issued:
22