SECTION 4: TROUBLESHOOTING
COMMON PROBLEMS (EXPORT UNITS)
Problem: Prime switch does not activate sanitizer pump.
1.Faulty prime switch. With the prime switch in the prime position, check for voltage between the GREY and WHITE/RED wires to switch. If 220V, replace the switch.
2.Faulty delime switch. With the delime switch in the DELIME position, check for voltage between the WHITE/BLACK and WHITE/RED wires to the delime switch. If 220V, replace the delime switch.
Problem: Detergent not feeding; rinse aid feeds okay.
1.Misadjusted cam. Adjust detergent cam on cam timer.
2.Faulty detergent microswitch on cam timer. When the detergent cam is in the home position, measure voltage between ORANGE and GREY/ WHITE wires. If 220V, replace the microswitch.
Problem: Rinse aid not feeding, detergent feeds okay.
1.Misadjusted cam. Adjust rinse aid cam on cam timer.
2.Faulty rinse aid microswitch on cam timer. When the rinse aid cam is in the home position, measure the voltage between the ORANGE and ORANGE/YELLOW wires. If 220V, replace the microswitch.
Problem: Sanitizer pump does not run during the cycle, but runs when primed.
1.Loose or broken wire. Tighten connections to microswitch.
2.Faulty sanitizer microswitch on cam timer. When sanitizer cam is in home position, measure voltage between ORANGE and GREY wires on the microswitch. If 220V, replace switch.