Jackson CONSERVER AXL2, CONSERVER XL2 Problem Machine will not fill, other functions work

Page 40

SECTION 4: TROUBLESHOOTING

COMMON PROBLEMS (EXPORT UNITS)

Problem: Machine will not fill, other functions work.

1.Y-strainer plugged. Clean strainer.

2.Water valve(s) turned off. Turn on water valves.

3.Faulty solenoid valve diaphragm. Replace diaphragm, clean foreign material out of valve body and orifices.

4.Faulty solenoid coil. If coil has voltage but no continuity, replace coil (continuity is measured across coil connectors with wires removed).

5.Faulty fill microswitch. Will not fill during cycle only. During fill, measure between the ORANGE and WHITE/GREEN wires. If 220V, adjust or replace switch).

6.Faulty OFF/ON/FILL switch. Depress switch, measure between BLACK and WHITE/GREEN wire. If 220V, replace switch.

Problem: Machine fills continuously, only when the power is on.

1.Faulty fill microswitch. Repair/replace switch.

2.Cam timer stalled in fill position. If cam timer is not rotating, check the voltage to the timer motor. If 220V when door is closed, replace the timer motor.

3.Shorted OFF/ON/FILL switch. Check voltage between BLACK and WHITE/GREEN connections of the switch in the "ON" position. If you do not read 220V, replace switch.

Problem: Wash motor does not run, other functions work, motor runs only when the wash relay is manually pushed down.

1.Loose wire connection to microswitch, relay, or contactor. Tighten wires.

2.Faulty wash cam microswitch. During wash cycle, check voltage between ORANGE and BLACK/ORANGE wires on the microswitch. If 220V, replace the switch.

3.Faulty delime switch. During wash cycle, check the voltage between the two BLACK/ ORANGE wires (not jumpers). If 220V, replace the delime switch.

Problem: Wash motor does not run, other functions work, motor runs only when the wash relay is manually pushed down.

1.Faulty control relay. Check the voltage across relay contacts #7 & #4. If 220V during the wash cycle, replace the relay.

2.Faulty wash relay. Check voltage at relay coil between ORANGE/BLACK and WHITE wires. If you read 220V, coil is faulty. Replace the relay.

Problem: Wash motor does not run even when the wash relay is manually depressed; other functions work.

1.Loose wire connections to motor, delime switch, or from contactors. Tighten wires.

2.Mechanical binding in pump. If motor has correct incoming voltage, and its overload is tripping, repair or replace the pump.

3.Mechanical binding in pump. On end of motor, opposite pump, remove endcap. With large slot type screwdriver, fit into slot in end of shaft. Turn to dislodge. Run motor as normal. If it still does not run, replace motor.

4.Faulty wash motor. If the motor has the correct incoming voltage and the pump is okay, replace the motor.

5.Faulty wash relay. With the wash relay pushed in, check the voltage between T1 and L1 of the relay. If 220V, replace the relays.

6.High or low voltage problem. Check voltage at motor and at power terminal block. Compare to electrical specifications.

Problem: Wash motor runs continuously.

1.The NORMAL/DELIME switch is in the Delime position. Place the switch in the Normal position.

2.Wash relay contacts are welded closed. Turn machine off. If wash relay doesn't release, replace contactor.

3.Cam timer stalled in wash or rinse cycle. If cam timer is not rotating, check the voltage to the timer motor. If no voltage when the door is closed, check wires and/or replace motor.

4.Wash motor microswitch faulty. Tighten connections, make sure switch makes contact, replace if necessary.

Problem: Sanitizer pump doesn't run during the cycle or through the use of the prime switch.

1.Loose motor terminal wire. Tighten connections.

2.Faulty sanitizer pump motor. If you read 220V at the sanitizer motor terminals during the sanitizer feed cycle, replace the motor.

Conserver XL Series Technical Manual 7610-002-10-23

Issued: 11-28-2007 Revised: N/A

33

Image 40
Contents INSTALLATION/OPERATION Technical Manual Manufacturers Warranty ONE Year Limited Parts & Labor WarrantyStop Pare Arret Revision Made Applicable Details Date ECN Model Serial No Installation Date Service Rep. Name Phone No Nomenclature for the Models Covered in this ManualTable of Contents Electrical Diagrams Service Repair CentersSection Specification Information Specification Information Operating Cycle Seconds Wash TimeTank Capacity Minimum Wash Pump CapacityTemperatures Operating Cycle SecondsDimensions Conserver AXL Dimensions Conserver AXL2 Dimensions Conserver AXL2-CML Rdimensions Conserver AXL2-CMR Dimensions Conserver XL Starting with S/N 04D10286 25mmSection Dimensions Conserver XL2-CML Dimensions Conserver XL2-CMR 204 526mm 441 1130mm 481 1232mmXLS Bowl Option Table Dimensions Straight Through InstallationSection INSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions Installation InstructionsElectrical Instructions Priming Chemical Feeder Pumps First-aid instructionsOperation Instructions INSTALLATION/OPERATION Instructions CAM Timer Operation INSTALLATION/OPERATION Instructions Mechanical Timer Timing Sequence Seconds Into Cycle INSTALLATION/OPERATION Instructions Universal Timer Programming Instructions Section Preventative Maintenance Preventative Maintenance Preventative MaintenanceSection Troubleshooting Section Common Problems Domestic Units TroubleshootingProblem Machine cycles continuously Problem Wash motor runs continuously Problem Machine will not fill, other functions workProblem Machine will not hold water Problem Machine runs with door open Problem Low pumped water pressureProblem Machine keeps tripping the service breaker Problem Machine will not drainProblem Detergent not feeding rinse aid feeds okay Problem Prime switch does not activate sanitizer pumpProblem Rinse aid not feeding, detergent feeds okay Common Problems Export Units Problem Machine will not fill, other functions work Problem Machine runs with door open Problem Prime switch does not activate sanitizer pump Section Parts Section Control BOX Assemblies Universal Timer Parts SectionQTY Description Control BOX Assemblies Mechanical Timer Control BOX Assembly with Mechanical Timer XLS Bowl Option Parts Section Mechanical 8 CAM Timer MicroswitchTimer Motor QtyChemical Feeder Pump Assembly 04320-002-82-28Hood Assembly Conserver XL2 Hood Assembly Cantilever ARM Double Bracket Mount Arm, Cantilever, Conserver XL Prior to S/N 04D10286 Conserver XL2 Cantilever ARM Assembly Single Bracket Mount False Panel Weldment Conserver XL2 TUB Assembly Left Front View Conserver XL2 Series TUB Assembly Right Front View Conserver XL2 Series Frame Weldment & Accumulator Incoming Plumbing Assemblies Plumbing AssemblyConserver AXL Incoming Solenoid Valve & 3/4 NPT Vacuum Breaker Repair Parts Kits Complete 110 Volt Solenoid Valve AssemblyCoil & Housing only Complete 240 Volt Solenoid Valve AssemblyConserver XL Wash Motor Assembly Motor & Pump Assembly Other parts not shownWash Manifold Assembly Drain Solenoid Assembly Miscellaneous Parts CML Assembly Options Represents an item not shown CMR Assembly Options Hood Weldment Conserver XL2-CMR Shown Conserver XL Hood Assembly Prior to S/N 04D10286 Conserver XL Door & Wrap Assemblies Prior to S/N 04D10286 Conserver XL Front DoorLower Frame, Conserver XL False Panel Installation False panel positioned in unitSection Electrical Schematics Electrical Schematics Conserver AXL 115 Volt 60 Hertz Single PhaseConserver AXL2 115 Volt 60 Hertz Single Phase Conserver AXL2-CML/CMR 115 Volt 60 Hertz Single Phase Conserver AXL2-CML/CMR 208-230 Volt 60 Hertz Single Phase Conserver Axls 115 Volt 60 Hertz Single Phase Conserver AXLS2 115 Volt 60 Hertz Single Phase Conserver XL Mechanical Timer 115 Volt 60 Hertz Single Phase Electrical Schematics Electrical Schematics Electrical Schematics Section Jackson Maintenance Repair Centers Jackson Maintenance & Repair Centers Alabama to FloridaService CO Florida to MarylandJackson Service Compa Maryland to NEW YorkCertified Service Center Rons Service NEW York to PennsylvaniaRhode Island to Wisconsin CENTER, INCWisconsin to WYOMING/INTERNATIONAL