Jackson jp-24b, JP-24 Electrical Installation Instructions, Installation/Operation Instructions

Page 12
ELECTRICAL INSTALLATION INSTRUCTIONS
Control Box Electrical Connection
Back of Unit Showing Chemical Connection Points

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

ELECTRICAL INSTALLATION INSTRUCTIONS

ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with the applicable portions of the National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.

Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit.

The dishmachine data plate is located on the front of the machine. Refer to the data plate for machine operating requirements,

machine voltage, total amperage load and serial number.

Ground Lug

Terminal Block

 

To install the incoming power lines, remove the kick panel. This will require tak- ing a phillips head screwdriver and removing the two screws at the bottom of the kick panel; open the door slightly while carefully lifting the kick panel up and out of the way. Install 3/4” conduit into the pre-punched holes in the back of the control box. Route power wires and connect to power block and grounding lug. Install the service wires (L1 and L2) to the appropriate terminals as they are marked on the terminal block. Install the grounding wire into the lug provided. It is recommended that “DE-OX” or another similar anti-oxidation agent be used on all power connections.

VOLTAGE CHECK: Ensure that the power switch is in the OFF position and apply power to the dishmachine. Check the incoming power at the terminal block and ensure it corresponds to the voltage listed on the data plate. If not, contact a qualified service agency to examine the problem. Do not run the dish- machine if the voltage is too high or too low. Shut off the service breaker and mark it as being for the dishmachine. Advise all proper personnel of any prob- lems and of the location of the service breaker. Replace the control box cover and tighten down the screws.

CHEMICAL CONNECTIONS: All chemical hookup loca- tions are located on the back of the dishmachine. Please refer to the drawing at the right for the correct connection point.

Brass Plug

Rinse Aid Fitting

Detergent Fitting

JP-24 Technical Manual 7610-002-49-79 Rev. D

Issued: 03-06-2006 Revised: N/A

7

Image 12
Contents TECHNICAL MANUAL FOR JACKSON MODELS JP-24 JP-24F JP-24B JP-24BFHOT WATER SANITIZING UNDERCOUNTER DISHMACHINES March 6 P/N 7610-002-49-79 Revision DPage REVISION MADEAPPLICABLE DETAILSModel Serial No Installation Date Service Rep. Name Phone No NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUALJP-24B TABLE OF CONTENTS I. SPECIFICATION INFORMATIONII. INSTALLATION/OPERATION INSTRUCTIONS PREVENTATIVE MAINTENANCESECTION SPECIFICATION INFORMATION SECTION 1 SPECIFICATION INFORMATION SPECIFICATIONS of the JP-24/JP-24F5 MINUTE TIMER OPERATING CYCLE SECONDS PERFORMANCE/CAPABILITIES OPERATING CAPACITY RACKS/HOURSPECIFICATIONS of the JP-24B/JP-24BF 5 MINUTE TIMER OPERATING CYCLE SECONDS WASH TIMEJP-24 DIMENSIONS DIMENSIONS30.5 cm 22 5/8”SECTION INSTALLATION/OPERATION INSTRUCTIONS SECTION 2 INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION INSTRUCTIONSELECTRICAL INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS DETERGENT CONTROL CYCLE COUNTER RETROFIT KIT INSTRUCTIONS SECTION PREVENTATIVE MAINTENANCE SECTION 3 PREVENTATIVE MAINTENANCE SECTION TROUBLESHOOTING SECTION 4 TROUBLESHOOTING SECTION COMMON PROBLEMSProblem Water overflow from bottom of door Problem Wash motor doesn’t operate on manual washProblem Machine doesn’t drain when “OFF/DRAIN” switch is pressed Problem No indication of pressureProblem Rinse water not at required temperature range SECTION SERVICE PROCEDURES SECTION 5 SERVICE PROCEDURES RINSE SOLENOID VALVE REPAIR PARTS KITPREPARATION TOOLS REQUIREDRINSE SOLENOID VALVE REPAIR PARTS KIT CONTINUED 13. Slowly remove the valve bonnet. Note The spring for the plunger is located directly under the bonnet and may come free if you are not careful. Remove the plunger, spring and valve bonnet and place to the side AFTER MAINTENANCE ACTIONS SPECIAL PARTSSolenoid Valve Plunger Kit Includes plunger and spring Part number VACUUM BREAKER REPAIR PARTS KIT VACUUM BREAKER REPAIR PARTS KIT CONTINUED REPLACING THE PUMP MOTOR/REPLACING THE HEATER REPLACING THE PUMP MOTORREPLACING THE BOOSTER TANK HEATER HeaterREPLACING THE DRAIN VALVE REPLACING THE DRAIN VALVE MINAL ON THE MOTORReplacing the Drain Valve RINSE REGULATING THERMOSTAT REPLACEMENT Remove the thermostat bracket mounting nuts with the 3/8” nutdriver 9. Note regardless of the unit this is being done to, the con- cept is to ensure that the thermostat cannot come into contact with the heater leads or interfere with the placement of any covers SPECIAL NOTES SECTION PARTS SECTION GAUGE PANEL ASSEMBLY SECTION 6 PARTS SECTIONITEM QTY DESCRIPTION Mfg. NoELECTRICAL PANEL ASSEMBLY JP-24/F 208-240 VOLT DESCRIPTIONELECTRICAL PANEL ASSEMBLY JP-24B/BF 208-240 VOLT ELECTRICAL PANEL ASSEMBLY JP-24B/BF 460 VOLT This panel is used with the following External Control Box Option AMTRAK External Control Box OptionMfg. No ELECTRICAL PANEL ASSEMBLY EXTERNAL OPTION & AMTRAK OPTION FRONT VIEW EXTERNAL OPTIONINSIDE VIEW of AMTRAK & EXTERNAL OPTIONS RIGHT SIDE VIEW AMTRAK OPTIONELECTRICAL PANEL ASSEMBLY EXTERNAL OPTION & AMTRAK OPTION CONTINUED KICK PLATE ASSEMBLY Decal, Power Disconnect Warning 09905-021-47-07Nut, Nylon Wing, 1/4”-20 Control Panel Assembly 05700-011-40-93 Control Panel Only 460 Control Panel Assembly 05700-002-18-38Vacuum Breaker Assembly INCOMING PLUMBING ASSEMBLY JP-24/JP-24FINCOMING PLUMBING ASSEMBLIES JP-24B/JP-24BF RINSE STIFFENER/RINSE HUB WELDMENT Connects to Rinse Injector Connects to Rinse StiffenerComplete 110 Volt Solenoid Valve Assembly, 1/2” Coil & Housing only, 1/2”Complete 220 Volt Solenoid Valve Assembly, 1/2” Complete Vacuum Breaker Assembly, 1/2” NPTDRAIN VALVE ASSEMBLY SECTION 6 PARTS SECTIONDRAIN PLUMBING ASSEMBLY WASH MOTOR TO WASH TUB ASSEMBLY Phase RINSE TANK & COMPONENTS/STRIP HEATER KITJP-24B/BFRINSE TANK 40F RiseDOOR ASSEMBLY Order this entire assembly usingDoor Latch Assembly MISCELLANEOUS DOOR SUB-ASSEMBLIESWash Arm Assembly Rinse Arm AssemblyRINSE ARM & WASH ARM ASSEMBLIES FRAME & PANEL COMPONENTS/MISCELLANEOUS PARTS CYCLE COUNTER RETROFIT KIT SECTION ELECTRICAL SCHEMATICS SECTION 7 ELECTRICAL SCHEMATICS JP-24/JP-24F 208-230 VOLT - 50/60 HERTZ - SINGLE PHASEJP-24B/JP-24BF 208-230 VOLT - 50/60 HERTZ - SINGLE PHASE JP-24B/JP-24BF 460 VOLT - 60 HERTZ - THREE PHASE