Jackson JP-24BF, jp-24b Service Procedures, Preparation, Tools Required, Time Required, Steps

Page 22
SECTION 5: SERVICE PROCEDURES

SECTION 5: SERVICE PROCEDURES

RINSE SOLENOID VALVE REPAIR PARTS KIT

These dishmachines are equipped with electrical solenoid valves to allow for automatic fill and rinse. These valves are designed to specific tolerances and design aspects that must be met in order to function properly.

Jackson offers repair kits for replacing some of the wear items associated with solenoid valves which will allow you to save money in that replacement of these parts can take place without removing the solenoid valve from the plumbing assembly.

The instructions provided here are for maintenance personnel only. Unauthorized persons should not attempt any of the steps contained in these instructions.

Warning: many of the instructions and steps within this document require the use of tools. Only autho- rized personnel should ever perform any maintenance procedure on the dishmachine!

PREPARATION

1.Power must be secured to the unit at the service breaker. Tag or lock out the service breaker to prevent acci- dental or unauthorized energizing of the machine.

2.Ensure that incoming water to the machine is secured either by use of a shut-off valve or disconnecting the incoming water line.

TOOLS REQUIRED

The following tools will be needed to perform this maintenance evolution:

1.Small flathead screwdriver

2.Medium flathead screwdriver

2.Needle nose pliers

3.5/16” nutdriver

4.Channel locks

5.12” pipe wrench

TIME REQUIRED

It is estimated that it will take (1) person twenty min- utes to perform this task, not including all of the items indicat- ed in the section entitled “PREPARATION”.

STEPS

1.Remove the top screw with the 5/16” nutdriver. Remove the screw and the data plate and set to the side.

Removing the top screw

2.With the top screw and data plate removed, grasp the sole- noid coil and gently pull up. The coil should slide up, allowing you to remove it from the valve bonnet. If you are wanting to replace the coil, continue on with Step 3. If you are wanting to replace some of the internal components of the valve, proceed to step 12.

IMPORTANT NOTES

Removing the coil

1.Read these instructions thoroughly before attempt- ing this maintenance evolution. Become familiar with the parts and what actions need to be taken. This will save time in the long run!

2.The procedures demonstrated in this manual are shown being performed on an AJ-44C rack conveyor dishma- chine. The actual maintenance steps, however, apply to any Parker style solenoid valve found on a Jackson dishmachine.

3.NOTE: Replacing the solenoid coil requires working with the wiring of your machine. It is important that all wiring main- tenance be performed by qualified personnel. Always verify the wiring steps presented in this instruction with the schemat- ic that shipped with the unit. A current schematic can also be found in the unit’s installation manual. Before beginning any step that involves working with wiring, ensure that the steps located in the section entitled “Preparation” have been per- formed. Power must be secured to the machine at the service breaker. Failure to do so could result in severe injury to main- tenance personnel.

JP-24 Technical Manual 7610-002-49-79 Rev. D

Issued: 03-06-2006 Revised: N/A

17

Image 22
Contents HOT WATER SANITIZING UNDERCOUNTER DISHMACHINES TECHNICAL MANUALFOR JACKSON MODELS JP-24 JP-24F JP-24B JP-24BF March 6 P/N 7610-002-49-79 Revision DPage APPLICABLE REVISIONMADE DETAILSNOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL Model Serial No Installation Date Service Rep. Name Phone NoJP-24B II. INSTALLATION/OPERATION INSTRUCTIONS TABLE OF CONTENTSI. SPECIFICATION INFORMATION PREVENTATIVE MAINTENANCESECTION SPECIFICATION INFORMATION 5 MINUTE TIMER OPERATING CYCLE SECONDS SECTION 1 SPECIFICATION INFORMATIONSPECIFICATIONS of the JP-24/JP-24F PERFORMANCE/CAPABILITIES OPERATING CAPACITY RACKS/HOURSPECIFICATIONS of the JP-24B/JP-24BF 5 MINUTE TIMER OPERATING CYCLE SECONDS WASH TIME30.5 cm JP-24 DIMENSIONSDIMENSIONS 22 5/8”SECTION INSTALLATION/OPERATION INSTRUCTIONS SECTION 2 INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION INSTRUCTIONSELECTRICAL INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS DETERGENT CONTROL CYCLE COUNTER RETROFIT KIT INSTRUCTIONS SECTION PREVENTATIVE MAINTENANCE SECTION 3 PREVENTATIVE MAINTENANCE SECTION TROUBLESHOOTING Problem Water overflow from bottom of door SECTION 4 TROUBLESHOOTING SECTIONCOMMON PROBLEMS Problem Wash motor doesn’t operate on manual washProblem No indication of pressure Problem Machine doesn’t drain when “OFF/DRAIN” switch is pressedProblem Rinse water not at required temperature range SECTION SERVICE PROCEDURES PREPARATION SECTION 5 SERVICE PROCEDURESRINSE SOLENOID VALVE REPAIR PARTS KIT TOOLS REQUIREDRINSE SOLENOID VALVE REPAIR PARTS KIT CONTINUED 13. Slowly remove the valve bonnet. Note The spring for the plunger is located directly under the bonnet and may come free if you are not careful. Remove the plunger, spring and valve bonnet and place to the side SPECIAL PARTS AFTER MAINTENANCE ACTIONSSolenoid Valve Plunger Kit Includes plunger and spring Part number VACUUM BREAKER REPAIR PARTS KIT VACUUM BREAKER REPAIR PARTS KIT CONTINUED REPLACING THE BOOSTER TANK HEATER REPLACING THE PUMP MOTOR/REPLACING THE HEATERREPLACING THE PUMP MOTOR HeaterMINAL ON THE MOTOR REPLACING THE DRAIN VALVE REPLACING THE DRAIN VALVEReplacing the Drain Valve RINSE REGULATING THERMOSTAT REPLACEMENT Remove the thermostat bracket mounting nuts with the 3/8” nutdriver 9. Note regardless of the unit this is being done to, the con- cept is to ensure that the thermostat cannot come into contact with the heater leads or interfere with the placement of any covers SPECIAL NOTES SECTION PARTS SECTION ITEM QTY DESCRIPTION GAUGE PANEL ASSEMBLYSECTION 6 PARTS SECTION Mfg. NoELECTRICAL PANEL ASSEMBLY JP-24/F 208-240 VOLT DESCRIPTIONELECTRICAL PANEL ASSEMBLY JP-24B/BF 208-240 VOLT ELECTRICAL PANEL ASSEMBLY JP-24B/BF 460 VOLT AMTRAK External Control Box Option This panel is used with the following External Control Box OptionMfg. No INSIDE VIEW of AMTRAK & EXTERNAL OPTIONS ELECTRICAL PANEL ASSEMBLY EXTERNAL OPTION & AMTRAK OPTIONFRONT VIEW EXTERNAL OPTION RIGHT SIDE VIEW AMTRAK OPTIONELECTRICAL PANEL ASSEMBLY EXTERNAL OPTION & AMTRAK OPTION CONTINUED Nut, Nylon Wing, 1/4”-20 Control Panel Assembly 05700-011-40-93 KICK PLATE ASSEMBLYDecal, Power Disconnect Warning 09905-021-47-07 Control Panel Only 460 Control Panel Assembly 05700-002-18-38Vacuum Breaker Assembly INCOMING PLUMBING ASSEMBLY JP-24/JP-24FINCOMING PLUMBING ASSEMBLIES JP-24B/JP-24BF RINSE STIFFENER/RINSE HUB WELDMENT Connects to Rinse Injector Connects to Rinse StiffenerComplete 220 Volt Solenoid Valve Assembly, 1/2” Complete 110 Volt Solenoid Valve Assembly, 1/2”Coil & Housing only, 1/2” Complete Vacuum Breaker Assembly, 1/2” NPTDRAIN VALVE ASSEMBLY SECTION 6 PARTS SECTIONDRAIN PLUMBING ASSEMBLY WASH MOTOR TO WASH TUB ASSEMBLY JP-24B/BFRINSE TANK PhaseRINSE TANK & COMPONENTS/STRIP HEATER KIT 40F RiseDOOR ASSEMBLY Order this entire assembly usingDoor Latch Assembly MISCELLANEOUS DOOR SUB-ASSEMBLIESRinse Arm Assembly Wash Arm AssemblyRINSE ARM & WASH ARM ASSEMBLIES FRAME & PANEL COMPONENTS/MISCELLANEOUS PARTS CYCLE COUNTER RETROFIT KIT SECTION ELECTRICAL SCHEMATICS SECTION 7 ELECTRICAL SCHEMATICS JP-24/JP-24F 208-230 VOLT - 50/60 HERTZ - SINGLE PHASEJP-24B/JP-24BF 208-230 VOLT - 50/60 HERTZ - SINGLE PHASE JP-24B/JP-24BF 460 VOLT - 60 HERTZ - THREE PHASE