Jackson jp-24b SPECIFICATIONS of the JP-24B/JP-24BF, Specification Information, Temperatures

Page 8
SPECIFICATIONS of the JP-24B/JP-24BF
(21.5) 5.65
(11.4) 3
(65.6°C) 150°F (82.2°C) 180°F
262
28
10
5

SECTION 1: SPECIFICATION INFORMATION

SPECIFICATIONS of the JP-24B/JP-24BF

PERFORMANCE/CAPABILITIES

OPERATING CAPACITY (RACKS/HOUR)

RACKS PER HOUR

DISHES PER HOUR

30

600

ELECTRICAL REQUIREMENTS

WASH MOTOR HP

3/4

NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip cir-

GLASSES PER HOUR

OPERATING CYCLE (SECONDS)

WASH TIME

DRAIN TIME

RINSE TIME

TOTAL CYCLE TIME (MINUTES)

600cuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is dis- played here. Always verify with your electrical service con- tractor that your circuit protection is adequate and meets all

applicable national and local codes. These numbers are pro-

82

vided in this manual simply for reference and may change

28

without notice at any given time.

 

10

 

2

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

 

VOLTS PH HZ RATINGS

AMPS

CIRCUIT

5 MINUTE TIMER OPERATING CYCLE (SECONDS) WASH TIME

DRAIN TIME

RINSE TIME

TOTAL CYCLE TIME (MINUTES)

TANK CAPACITY (LITERS) (GALLONS)

WASH TANK

RINSE TANK

208

1

50

6.7KW

40

50 AMP

230

1

50

8.2KW

43

60 AMP

208

1

50

8.2KW

47

60 AMP

230

1

50

10KW

51

70 AMP

220

1

50

9.15KW

48

60 AMP

208

1

60

6.7KW

39

50 AMP

230

1

60

8.2KW

46

60 AMP

208

1

60

8.2KW

42

60 AMP

230

1

60

10KW

50

70 AMP

460

1

60

480/8.2KW

11

15 AMP

460

1

60

480/9.6KW

14

20 AMP

TEMPERATURES

WASH --- (MINIMUM)

RINSE --- (MINIMUM)

WATER REQUIREMENTS

INLET TEMPERATURE (40° Booster Heater) (82.2°C) 140°F INLET TEMPERATURE (70° Booster Heater) (43.3°C) 110°F

GALLONS PER HOUR

(198.7L) 52.3

WATER LINE SIZE I.P.S. (Minimum)

(1.27 cm) 1/2”

DRAIN LINE SIZE I.P.S. (Minimum)

(3.81 cm) 1 1/2”

FLOW PRESSURE P.S.I.

20A5

FLOW, GALLONS PER MINUTE

(27L) 7.1

NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.

JP-24 Technical Manual 7610-002-49-79 Rev. D

Issued: 03-06-2006 Revised: N/A

3

Image 8
Contents TECHNICAL MANUAL FOR JACKSON MODELS JP-24 JP-24F JP-24B JP-24BFHOT WATER SANITIZING UNDERCOUNTER DISHMACHINES March 6 P/N 7610-002-49-79 Revision DPage REVISION MADEAPPLICABLE DETAILSJP-24B Model Serial No Installation Date Service Rep. Name Phone NoNOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL TABLE OF CONTENTS I. SPECIFICATION INFORMATIONII. INSTALLATION/OPERATION INSTRUCTIONS PREVENTATIVE MAINTENANCESECTION SPECIFICATION INFORMATION SECTION 1 SPECIFICATION INFORMATION SPECIFICATIONS of the JP-24/JP-24F5 MINUTE TIMER OPERATING CYCLE SECONDS PERFORMANCE/CAPABILITIES OPERATING CAPACITY RACKS/HOURSPECIFICATIONS of the JP-24B/JP-24BF 5 MINUTE TIMER OPERATING CYCLE SECONDS WASH TIMEJP-24 DIMENSIONS DIMENSIONS30.5 cm 22 5/8”SECTION INSTALLATION/OPERATION INSTRUCTIONS SECTION 2 INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION INSTRUCTIONSELECTRICAL INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS DETERGENT CONTROL CYCLE COUNTER RETROFIT KIT INSTRUCTIONS SECTION PREVENTATIVE MAINTENANCE SECTION 3 PREVENTATIVE MAINTENANCE SECTION TROUBLESHOOTING SECTION 4 TROUBLESHOOTING SECTION COMMON PROBLEMSProblem Water overflow from bottom of door Problem Wash motor doesn’t operate on manual washProblem Rinse water not at required temperature range Problem Machine doesn’t drain when “OFF/DRAIN” switch is pressedProblem No indication of pressure SECTION SERVICE PROCEDURES SECTION 5 SERVICE PROCEDURES RINSE SOLENOID VALVE REPAIR PARTS KITPREPARATION TOOLS REQUIREDRINSE SOLENOID VALVE REPAIR PARTS KIT CONTINUED 13. Slowly remove the valve bonnet. Note The spring for the plunger is located directly under the bonnet and may come free if you are not careful. Remove the plunger, spring and valve bonnet and place to the side Solenoid Valve Plunger Kit Includes plunger and spring Part number AFTER MAINTENANCE ACTIONSSPECIAL PARTS VACUUM BREAKER REPAIR PARTS KIT VACUUM BREAKER REPAIR PARTS KIT CONTINUED REPLACING THE PUMP MOTOR/REPLACING THE HEATER REPLACING THE PUMP MOTORREPLACING THE BOOSTER TANK HEATER HeaterReplacing the Drain Valve REPLACING THE DRAIN VALVE REPLACING THE DRAIN VALVEMINAL ON THE MOTOR RINSE REGULATING THERMOSTAT REPLACEMENT Remove the thermostat bracket mounting nuts with the 3/8” nutdriver 9. Note regardless of the unit this is being done to, the con- cept is to ensure that the thermostat cannot come into contact with the heater leads or interfere with the placement of any covers SPECIAL NOTES SECTION PARTS SECTION GAUGE PANEL ASSEMBLY SECTION 6 PARTS SECTIONITEM QTY DESCRIPTION Mfg. NoELECTRICAL PANEL ASSEMBLY JP-24/F 208-240 VOLT DESCRIPTIONELECTRICAL PANEL ASSEMBLY JP-24B/BF 208-240 VOLT ELECTRICAL PANEL ASSEMBLY JP-24B/BF 460 VOLT Mfg. No This panel is used with the following External Control Box OptionAMTRAK External Control Box Option ELECTRICAL PANEL ASSEMBLY EXTERNAL OPTION & AMTRAK OPTION FRONT VIEW EXTERNAL OPTIONINSIDE VIEW of AMTRAK & EXTERNAL OPTIONS RIGHT SIDE VIEW AMTRAK OPTIONELECTRICAL PANEL ASSEMBLY EXTERNAL OPTION & AMTRAK OPTION CONTINUED KICK PLATE ASSEMBLY Decal, Power Disconnect Warning 09905-021-47-07Nut, Nylon Wing, 1/4”-20 Control Panel Assembly 05700-011-40-93 Control Panel Only 460 Control Panel Assembly 05700-002-18-38Vacuum Breaker Assembly INCOMING PLUMBING ASSEMBLY JP-24/JP-24FINCOMING PLUMBING ASSEMBLIES JP-24B/JP-24BF RINSE STIFFENER/RINSE HUB WELDMENT Connects to Rinse Injector Connects to Rinse StiffenerComplete 110 Volt Solenoid Valve Assembly, 1/2” Coil & Housing only, 1/2”Complete 220 Volt Solenoid Valve Assembly, 1/2” Complete Vacuum Breaker Assembly, 1/2” NPTDRAIN VALVE ASSEMBLY SECTION 6 PARTS SECTIONDRAIN PLUMBING ASSEMBLY WASH MOTOR TO WASH TUB ASSEMBLY Phase RINSE TANK & COMPONENTS/STRIP HEATER KITJP-24B/BFRINSE TANK 40F RiseDOOR ASSEMBLY Order this entire assembly usingDoor Latch Assembly MISCELLANEOUS DOOR SUB-ASSEMBLIESRINSE ARM & WASH ARM ASSEMBLIES Wash Arm AssemblyRinse Arm Assembly FRAME & PANEL COMPONENTS/MISCELLANEOUS PARTS CYCLE COUNTER RETROFIT KIT SECTION ELECTRICAL SCHEMATICS SECTION 7 ELECTRICAL SCHEMATICS JP-24/JP-24F 208-230 VOLT - 50/60 HERTZ - SINGLE PHASEJP-24B/JP-24BF 208-230 VOLT - 50/60 HERTZ - SINGLE PHASE JP-24B/JP-24BF 460 VOLT - 60 HERTZ - THREE PHASE