Jackson JP-24F Vacuum Breaker Repair Parts Kit Continued, Service Procedures, Special Parts

Page 27
VACUUM BREAKER REPAIR PARTS KIT (CONTINUED)

SECTION 5: SERVICE PROCEDURES

VACUUM BREAKER REPAIR PARTS KIT (CONTINUED)

Removing the plunger

6.Your repair kit comes with a new plunger. Examine the old one and ensure that the mating surface is not damaged or cut. Also inspect the rubber seal on the top of the plunger to ensure it is in good condition and not torn.

Examining the seal ring on the plunger

7.If any of these conditions are present, replace the old plunger with the new one from your kit. Verify that the new plunger is also free from defects. If it is not, contact Jackson immediately.

8.The plunger should drop into the vacuum breaker and seat. Ensure it is not flipped upside down (the orange seal ring should be up towards the top of the vacuum breaker).

9.Pick up the cap and examine it. With a soft towel, remove any grit, grime or debris that may have gotten caught in the threads of both the cap retainer or the vacuum breaker body. There is an O-ring that should be present on the cap retainer as well. Regardless of the condition of the plunger, this O-ring should be replaced once the cap is removed. Using a small flathead screwdriver, remove the old O-ring.

Replacing the O-ring

10.With the new O-ring in place, screw the cap back on the vacuum breaker body. The cap needs to only be hand tight (snug).

AFTER MAINTENANCE ACTIONS

1. Reconnect the incoming water (if disconnected) and turn on. Then restore power to the unit. Run the unit for at least 10 minutes to ensure there are no leaks. If any prob- lems arise please contact Jackson.

SPECIAL PARTS

Vacuum breaker repair kit:

For 1/2” NPT order 06401-003-06-23

Complete Vacuum Breaker Assembly

Part number 04820-003-06-13 (1/2”)

Examining the plunger seating surface

JP-24 Technical Manual 7610-002-49-79 Rev. D

Issued: 03-06-2006 Revised: N/A

22

Image 27
Contents March 6 P/N 7610-002-49-79 Revision D TECHNICAL MANUALFOR JACKSON MODELS JP-24 JP-24F JP-24B JP-24BF HOT WATER SANITIZING UNDERCOUNTER DISHMACHINESPage DETAILS REVISIONMADE APPLICABLEModel Serial No Installation Date Service Rep. Name Phone No NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUALJP-24B PREVENTATIVE MAINTENANCE TABLE OF CONTENTSI. SPECIFICATION INFORMATION II. INSTALLATION/OPERATION INSTRUCTIONSSECTION SPECIFICATION INFORMATION PERFORMANCE/CAPABILITIES OPERATING CAPACITY RACKS/HOUR SECTION 1 SPECIFICATION INFORMATIONSPECIFICATIONS of the JP-24/JP-24F 5 MINUTE TIMER OPERATING CYCLE SECONDS5 MINUTE TIMER OPERATING CYCLE SECONDS WASH TIME SPECIFICATIONS of the JP-24B/JP-24BF22 5/8” JP-24 DIMENSIONSDIMENSIONS 30.5 cmSECTION INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION INSTRUCTIONS SECTION 2 INSTALLATION/OPERATION INSTRUCTIONSELECTRICAL INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS DETERGENT CONTROL CYCLE COUNTER RETROFIT KIT INSTRUCTIONS SECTION PREVENTATIVE MAINTENANCE SECTION 3 PREVENTATIVE MAINTENANCE SECTION TROUBLESHOOTING Problem Wash motor doesn’t operate on manual wash SECTION 4 TROUBLESHOOTING SECTIONCOMMON PROBLEMS Problem Water overflow from bottom of doorProblem Machine doesn’t drain when “OFF/DRAIN” switch is pressed Problem No indication of pressureProblem Rinse water not at required temperature range SECTION SERVICE PROCEDURES TOOLS REQUIRED SECTION 5 SERVICE PROCEDURESRINSE SOLENOID VALVE REPAIR PARTS KIT PREPARATIONRINSE SOLENOID VALVE REPAIR PARTS KIT CONTINUED 13. Slowly remove the valve bonnet. Note The spring for the plunger is located directly under the bonnet and may come free if you are not careful. Remove the plunger, spring and valve bonnet and place to the side AFTER MAINTENANCE ACTIONS SPECIAL PARTSSolenoid Valve Plunger Kit Includes plunger and spring Part number VACUUM BREAKER REPAIR PARTS KIT VACUUM BREAKER REPAIR PARTS KIT CONTINUED Heater REPLACING THE PUMP MOTOR/REPLACING THE HEATERREPLACING THE PUMP MOTOR REPLACING THE BOOSTER TANK HEATERREPLACING THE DRAIN VALVE REPLACING THE DRAIN VALVE MINAL ON THE MOTORReplacing the Drain Valve RINSE REGULATING THERMOSTAT REPLACEMENT Remove the thermostat bracket mounting nuts with the 3/8” nutdriver 9. Note regardless of the unit this is being done to, the con- cept is to ensure that the thermostat cannot come into contact with the heater leads or interfere with the placement of any covers SPECIAL NOTES SECTION PARTS SECTION Mfg. No GAUGE PANEL ASSEMBLYSECTION 6 PARTS SECTION ITEM QTY DESCRIPTIONDESCRIPTION ELECTRICAL PANEL ASSEMBLY JP-24/F 208-240 VOLTELECTRICAL PANEL ASSEMBLY JP-24B/BF 208-240 VOLT ELECTRICAL PANEL ASSEMBLY JP-24B/BF 460 VOLT This panel is used with the following External Control Box Option AMTRAK External Control Box OptionMfg. No RIGHT SIDE VIEW AMTRAK OPTION ELECTRICAL PANEL ASSEMBLY EXTERNAL OPTION & AMTRAK OPTIONFRONT VIEW EXTERNAL OPTION INSIDE VIEW of AMTRAK & EXTERNAL OPTIONSELECTRICAL PANEL ASSEMBLY EXTERNAL OPTION & AMTRAK OPTION CONTINUED Control Panel Only 460 Control Panel Assembly 05700-002-18-38 KICK PLATE ASSEMBLYDecal, Power Disconnect Warning 09905-021-47-07 Nut, Nylon Wing, 1/4”-20 Control Panel Assembly 05700-011-40-93INCOMING PLUMBING ASSEMBLY JP-24/JP-24F Vacuum Breaker AssemblyINCOMING PLUMBING ASSEMBLIES JP-24B/JP-24BF Connects to Rinse Injector Connects to Rinse Stiffener RINSE STIFFENER/RINSE HUB WELDMENTComplete Vacuum Breaker Assembly, 1/2” NPT Complete 110 Volt Solenoid Valve Assembly, 1/2”Coil & Housing only, 1/2” Complete 220 Volt Solenoid Valve Assembly, 1/2”SECTION 6 PARTS SECTION DRAIN VALVE ASSEMBLYDRAIN PLUMBING ASSEMBLY WASH MOTOR TO WASH TUB ASSEMBLY 40F Rise PhaseRINSE TANK & COMPONENTS/STRIP HEATER KIT JP-24B/BFRINSE TANKOrder this entire assembly using DOOR ASSEMBLYMISCELLANEOUS DOOR SUB-ASSEMBLIES Door Latch AssemblyWash Arm Assembly Rinse Arm AssemblyRINSE ARM & WASH ARM ASSEMBLIES FRAME & PANEL COMPONENTS/MISCELLANEOUS PARTS CYCLE COUNTER RETROFIT KIT SECTION ELECTRICAL SCHEMATICS JP-24/JP-24F 208-230 VOLT - 50/60 HERTZ - SINGLE PHASE SECTION 7 ELECTRICAL SCHEMATICSJP-24B/JP-24BF 208-230 VOLT - 50/60 HERTZ - SINGLE PHASE JP-24B/JP-24BF 460 VOLT - 60 HERTZ - THREE PHASE