Keating Of Chicago Fryer user manual Series 2000 2010 CPU Models Operating Instructions, Cooking

Page 9

Select "MELT" with solid shortening until liquid shortening is 1" from full mark then switch to the "FRY" position after packing shortening around burner tubes.

SHUTDOWN PROCEDURE

STEP 1.

Set thermostat to the "OFF" position.

STEP 2.

Turn "MAIN POWER" switch to the "OFF"

 

position. Its green light will go off.

STEP 3.

Turn gas supply valve to the "OFF" position.

STEP 4.

Check to make sure all burners and pilot are

 

extinguished.

SERIES 2000 - 2010 CPU MODELS

OPERATING INSTRUCTIONS

CPU CONTROL PANEL SERIES 2000

CPU CONTROL PANEL SERIES 2009

CPU CONTROL PANEL SERIES 2010

START-UP PROCEDURE

WARNING: DO NOT START FRYER WITHOUT

FIRST FILLING FRY POT.

STEP 1. Light mini pilot located next to the left burner when facing fryer.

STEP 2. Turn gas supply to the ‘ON’ position.

STEP 3. Depress the main power switch to the ‘ON’ position.

STEP 4. Make sure CPU is turned off.

STEP 5. Engage the (Push to Light) switch and hold until indicator light remains on or the pilot runner tube remains lit.

STEP 6. Turn the CPU on by pressing on/off button. STEP 7. Select melt cycle or heat cycle.

STEP 8. Select the desired temperature. See the computer manual for more information.

SHUTDOWN PROCEDURE

STEP 1. Turn CPU off by pressing the on/off button. STEP 2. Depress the main power switch to the off

position.

STEP 3. Turn gas supply to the "OFF" position. STEP 4. Wait five minutes before restarting or

relighting fryer.

SERIES 2000 CPU SPARK IGNITION MODELS

OPERATING INSTRUCTIONS

CPU SPARK IGNITION SERIES 2000

START-UP PROCEDURE

WARNING: DO NOT START FRYER WITHOUT

FIRST FILLING FRY POT.

STEP 1. Turn gas supply to the ‘ON’ position. STEP 2. Depress the main power switch to the ‘ON’

position.

STEP 3. Turn CPU to the ‘ON’ position. STEP 4. Select melt cycle or heat setting.

STEP 5. Select the desired temperature. See the computer manual for more information.

SHUTDOWN PROCEDURE

STEP 1. Turn CPU off by pressing the on/off button. STEP 2. Depress the main power switch to the ‘OFF’

position.

STEP 3. Turn gas supply to the "OFF" position. STEP 4. Wait five minutes before restarting or

relighting fryer.

COOKING

Keating's Instant Recovery® Gas Fryer is designed to provide maximum production efficiency and deliver high quality food products. Low- temperature cooking, highly polished stainless steel and a true COLD ZONE mean extended oil life. Follow cooking procedures on next page for your model.

Cold Zone

7

Image 9
Contents Instant Recovery GAS Fryer Series Post this Label in a Prominent Location On Your Unit If Equipment Arrives Damaged Suitable for NON Combustible Floors Ventilation Minimum ClearanceNational Code Requirement GAS Connections and Pipe SizeLeveling Installation Shutdown Procedure START-UP Procedure Filling AA Models Operating InstructionsSeries 2006 BB Models Operating Instructions START-UP ProcedureSeries 2006 BB Spark Ignition Operating Instructions Series 2000 BB Models Operating InstructionsSeries 2006 TS Models Series 2000 TS Models Operating InstructionsSeries 2009 TS Spark Ignition Models Operating Instructions First Filling FRY POTCooking Series 2000 2010 CPU Models Operating InstructionsTS Model Timer Operating Instructions Shutdown InstructionsOIL Breakdown Cleaning and BOIL-OUT For a Single Fryer Safe & Easy Filter Side View Preventive Maintenance Chart Time OPERATOR/OWNER Frame Occurrence SolutionHI-LIMIT Check BI-MONTHLY Thermostat CalibrationThermopile Readings TroubleshootingTroubleshooting Chart Service DiagnosisTroubleshooting Chart Troubleshooting Chart GAS Fryer Parts List Models with UNI-POT Pages 17 Ordering PartsDescription Models GAS Fryer Assembly Runner Pilot Assembly Series QTY. Description Control Panel AA & CM GAS SeriesQTY Description Control Panel BB GAS SeriesControl Panel BB Spark Ignition Series Magnetic Safety SwitchControl Panel TS GAS Series Control Panel BB SparkControl Panel TS GAS Series Series 2009 for ALL Other Models Control Panel TS SparkControl Panel TS Spark Ignition Series 2007 for 34 X 24 ModelCPU Control Panel Series Spark Ignition Design Variations Description QTY Basket Lift Power Supply BoxFigure 6-2Basket Lift AssemblyBasket Lift Power Supply BOX 2007 CPU & NON-CPU Series Electrical BOX Assembly GAS FryerAA 2007 Electrical Assembly with Safe & Easy Filter CM & AA 2000 Electrical Assembly Front DrainPage Electrical Assembly not shown to scale BB 2006 Electrical Assembly with Safe & Easy Filter 34 X 24 BB 2007 Electrical Assembly Front DrainPage BB 2006 Spark Ignition with Safe & Easy Filter TS 2000 Electrical AssemblyPage Page Page Page 34 X 24 TS 2007 Electrical Assembly Front Drain Page Electrical Assembly Spark Ignition with Safe & Easy Filter Page Page Page Basket Lift Electrical Assembly with CPU Models Series Page Page Keating Limited Warranty Card Service Information