Electrical connection IRL, U.K., ZA
All electrical work should be carried out in strict accordance with national and local safety regulations by a suitably qualified and competent service technician approved by Miele.
This appliance is supplied with a mains cable and plug for connection to a 230 - 240 V, 50 Hz single phase supply.
The voltage, connected load and fuse rating (where applicable) are given on the data plate situated at the front of the oven interior. Please ensure that these match the household mains supply.
Connection should be made via a fused connection unit or a fused plug and a suitable switched socket, or via a suitable isolator which complies with national and local safety regulations, and the on/off switch should be easily accessible after the appliance has been installed.
If the socket is not accessible after installation (depending on country) an additional means of disconnection must be provided for all poles.
When switched off there must be an
For extra safety it is advisable to install a residual current device with a trip current of 30 mA (in accordance with DIN VDE 0664, VDE 0100 Section 739).
If the cable is damaged a new cable must be fitted by a Miele approved ser- vice engineer.
If the appliance is connected via an isolator switch the plug must be cut off and rendered useless. The appliance
must then be connected to the mains supply by a suitably qualified person only.
Important U.K.
The wires in the mains lead of this appliance are coloured in accordance with the following code:
Green/yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wires in the mains lead of this appliance may not correspond with the markings identifying the terminals in your plug, proceed as follows:
The wire coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol z or coloured green or green and yellow.
The wire coloured blue must be connected to the terminal marked with the letter "N" or coloured black. The wire coloured brown must be connected to the terminal marked with the letter "L" or coloured red (U.K).
WARNING
THIS APPLIANCE MUST BE
EARTHED
55