Miele K 1801 Vi, K 1911 Vi, K 1901 Vi, K 1811 Vi installation instructions Electrical connection

Page 62

Electrical connection

￿Avoid the risk of electrical shock

-Plug into a grounded 3-prong outlet.

-Do not move the ground plug.

-Do not use an adapter.

-Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Improper connection of the equipment grounding conductor may result in electric shock. If you are in any doubt as to whether the appliance has been properly grounded, have the appliance checked by a qualified electrician or service technician.

Installation, repairs and other work by unqualified persons could be dangerous.

Before installing the appliance, verify that the voltage, load and circuit rating information found on the data plate match the household electrical supply.

If there are any questions regarding the electrical connection of this appliance to the power supply, please consult a licensed electrician or call the Miele Technical Service.

￿1-800-999-1360

￿1-800-565-6435

The appliance is supplied with a UL-listed, 3-wire power cord and NEMA 5-15 P plug ready for connection to a 120 V, 60 Hz supply.

The fuse rating is 15 amps.

The appliance requires a 3-wire receptacle.

The receptacle must be installed by a licensed electrician only.

In the case of side-by-side installations, a separate outlet must be used for each appliance. Ideally, the power outlet should be next to the appliance and easily accessible. Do not connect the appliance to the power supply by an extension cord. Extension cords do not guarantee the required safety of the appliance (danger of overheating).

If any changes are needed to the household wiring or power supply, this work must be performed by a qualified electrician.

62

Image 62
Contents En US, CA Contents Contents Important Safety Instructions Electrical SafetyInstallation UseSave These Instructions Disposal of your old applianceGuide to the refrigerator Control panel Turning the appliance On/Off Before using for the first timeBefore use Settings Using the settingsFunction Display text Custom settingsTurning the button sound On/Off Turning off for longer periods of time Door alarm Temperature and door alarmTemperature alarm Temperature display Setting the temperatureSetting the temperature in the refrigerator Temperature rangeTemperature unit Fahrenheit/Celsius SmartFresh drawers Storage temperaturesUsing the SmartFresh drawers HumidityFoods that are best stored under moist conditions Tips for storing food SmartFresh drawersFoods that are best stored under dry conditions Warmest area Using the refrigerator efficientlyDifferent storage zones Coldest areaSuperCool Switching on SuperCoolSwitching off SuperCool Automatic defrost Refrigerator and SmartFresh drawersDeli drawer Adjusting the interior fittingsMoving the shelves Replacing the drawerSmartFresh drawer To remove the shelf above the SmartFresh drawers Adjusting the door shelvesRemoving the storage shelf from above the deli drawer To better maintain your appliance avoid the following Cleaning and careRemove the cleaner promptly Aluminum frames Before cleaningCleaning the interior and accessories Humidity filters Door seals After cleaningVentilation slits Changing the light bulb Upper lightingSide lighting Frequently asked questions On very frequently Issue Possible fault Solution Compressor kicksAlarm indicator is For too longSssrrrrr Blubb, blubbClick CreakingAfter sales service MieleCarePage Installation instructions Disposal of an old appliance Caring for the environmentDisposal of packing materials Installation Installation siteFurniture/fixtures Installation nicheBase VentilationCustom door panels Installation optionsStainless steel panels Single columnSide panels Installation with partition using the Merging KitInstallation with partition without using the Merging Kit From 5/8 16 mm to 6 5/16 160 mmAdjusting the door opening angle optional accessory Front panel gap kit optional accessoryDoor dimensions open min C DimensionsDoor dimensions open min 18X118X1 30 762 mm 19X1 36 915 mm Niche dimensionsNiche width a Power supply Door front dimensions 18X1 15 381 mm 19X1 18 458 mmOptional accessories Installing the applianceTools needed for installation Before you beginAligning the housing unit Check the installation niche Before installationRemoteVision module installation Preparing the installation niche Mounting Accessories Anti-tip bracketsInstalling the appliance Securing an alternative anti-tip device Sliding the appliance into the installation space Aligning the appliance Attaching the appliance to the installation niche Installing the appliance Preparing the custom door Installing the appliance Attaching and aligning the custom door front Attaching the fixing brackets Attaching the covers Attaching the toe-kick cover Mounting the air separator Electrical connection RemoteVision optional accessory Accessing the RemoteVision control panel Selectable Description of function Options Status indicators Description of functionMasterCool control panel options for RemoteVision Page Page Alteration rights reserved Nr 169 670