SCCG50 & SCCP50
Service Manual
System Information
Overall: | Electrical Sequence: | ||
• | Refrigerant: 8 oz | A closed bin thermostat signals to the controller a | |
• | Compressor: Hermetic, 1300 BTUH, X HP | need for ice. The controller checks for water, if | |
water is needed , the controller opens the inlet | |||
• | Condenser: Forced draft | ||
water solenoid valve to fill the reservoir. The hot | |||
• | Fan blade: 5 blade, 7 inch | ||
gas valve is open to equalize the system. When the | |||
• | Evaporator: Inverted, 24 cube cells. Copper | ||
reservoir is full, the compressor, fan motor, water | |||
| cups attached to continuous serpentine | ||
| pump are switched on. After 5 seconds the hot gas | ||
• | Metering device: Cap tube | ||
valve shuts and ice making begins. | |||
|
|
•Defrost method: Hot gas bypass with water
| assist | Water is sprayed up into the inverted cup mold. As |
• | Spray method: 6 water jets | the water is cooled and ice begins to form in the |
• | Water charge: 40 ounces | cups, the temperature of the evaporator will fall. |
•Water valve: 115 volt solenoid, .19 GPM
• | Water fill time: Varies with harvest time & | The freeze cycle continues until the temperature of | |
the thermistor attached to the evaporator outlet | |||
| purge setting | ||
| tube falls to about zero degrees F. At that point the | ||
• | Spray pump: Pedestal type. | ||
controller starts a freeze cycle timer, whose default | |||
• | Drain pump: Magnetic drive, controlled by | ||
time is 10 minutes. At the end of the freeze cycle's | |||
| pressure switch | ||
| timed portion the controller switches to the harvest | ||
|
| ||
• | Purge method: Overflow standpipe | cycle. |
•Control method: Electronic
• Cycle control: Thermistor + timers | The harvest cycle begins with the controller | ||
• Freeze cycle timer: 10 minutes, + - 4 | stopping the water pump and fan motor. At the | ||
same time it opens the hot gas valve and the inlet | |||
• Harvest cycle timer: 20 seconds, + - 40 | |||
water solenoid valve. The ice is released by the | |||
• Cube size adjustment: Freeze timer change. | |||
combination of discharge refrigerant gas entering | |||
• Harvest cycle adjustment: Harvest timer | |||
the evaporator serpentine and warming up the | |||
| change | ||
| copper, plus the inlet water that flows to the | ||
|
| ||
• Bin control: Thermostat. Opens on | evaporator, floods across the plastic platen to | ||
| temperature fall, Cut Out: 35 degrees F. Cut | warm it up and be | |
| In 45 degrees F. Range is adjustable. | cubes drop individually and harvest continues until | |
|
| the thermistor attached to the suction line warms | |
Electrical Components: | up to about 50 degrees F. At that point a harvest | ||
|
| timer starts, whose default time is 20 seconds. At | |
• | Compressor | the end of that time the harvest cycle ends and the | |
• | Fan motor | freeze cycle restarts. |
•Spray pump motor
• | Drain pump motor | Bin control. | |
| |||
• | Drain pump switch | The machine's on and off modes are regulated by a | |
• Bin light - LED type | |||
bin thermostat. The cap tube for the bin thermostat | |||
|
| ||
• | Bin light switch - magnetic reed | is in the tube that holds the scoop. The machine | |
• | Inlet water solenoid valve | will only begin ice making when the thermostat's | |
• | Hot gas valve | contacts close. If the contacts | |
• | Transformer | temperature of the evaporator drops below a preset | |
point, the machine will stop. If the temperature is | |||
• | Controller | ||
below that point when the contact s open, the | |||
• | Water sensor | ||
machine will continue through a complete cycle | |||
• | Thermistor | ||
and stop at the end of the harvest cycle. | |||
|
|
•Bin thermostat
September 2008