Scotsman Ice SCCG50, SCCP50 service manual Custom Panel

Page 8

SCCG50 & SCCP50

Service Manual

Custom Panel

A custom panel of wood or other material not exceeding 15 lb can be attached to the door. Attachment is from the ice side of the door. Holes are provided in the door for this purpose.

To create and attach a custom panel:

Panel width: 14 7/8”

Panel height: Between 29 3/8” and 30 3/8”.

Panel thickness: 5/8” to ¾”

10.Mount panel to door using wood screws or supplied panel mounting screws.

Note: When installed Ice machine must be adjusted for height to position top of door to desired clearance.

1.Measure overall height of cabinet opening where ice machine will be (floor to bottom of countertop edge).

2.Determine desired kickplate space (from bottom of door to floor). This could be equal to the adjacent cabinet’s kickplate space or another space the user wants.

3.Subtract kickplate space from cabinet opening.

4.Subtract 1/8 or more for clearance space between top of door and bottom of countertop edge from cabinet opening. This is the maximum door length.

5.Cut panel to width.

6.Cut panel to length (cabinet space - kickplate space - top clearance = length).

7.Determine top of panel.

8.Mark hole locations using drawing on the back of these instructions. Drawing assumes top of panel will be flush with top of door. Measure hole locations from the top of the panel.

9.Drill pilot holes for wood screws. Use drill stop to prevent drilling through the panel.

 

 

13 9/16"

 

 

6 25/32"

13/16"

8 1/4"

4 1/8"

 

 

 

13/32"

 

14 11/16"

 

 

Ø

1/8"

 

TYP.(10)

 

13 31/64"

 

 

13/32"

{Centerline}

 

 

 

 

14 7/8"

303/8"

293/8"

June 2008

Page 8

Image 8
Contents Table of Contents IntroductionSpecifications LEG Adjustment Places Drain Flexible Tubing Cabinet LayoutAir flow Installation Overview Water QualityScale can shorten machine life Filters and TreatmentDoor Covering Door Panel Custom PanelDoor Panel Attachment Custom Panel Installation Notes Door swing changeInstallation Water & Drain Drain Pump Model drain installationGravity Drain Initial Start Up Installation check listElectrical Cube Size Adjustment Cube Size Change TableHarvest Time Adjustment Harvest Time TableReset time to clean indicator light Control SettingsAutomatic water purge enable / disable Use How to clean the condenser and winterize Condenser cleaningHow to remove scale from the ice making system System Information Water System Components Controller Maximum Harvest Time minutesPerformance Information Discharge Pressure Refrigeration SystemTime Thermistor Values Deg. F · Ohms Deg. F. · OhmsService Diagnosis Problem Likely Cause Probable SolutionMakes excessive noise Removal and Repair Evaporator Thermistor ControllerControl Panel TransformerRemoval and Repair Cabinet Removal Page Refrigeration Service