Scotsman Ice SCCG50, SCCP50 service manual Harvest Time Adjustment, Harvest Time Table

Page 14

SCCG50 & SCCP50

Service Manual

Harvest Time Adjustment

The harvest time can be adjusted so that all the ice harvests during the cycle, plus a few seconds extra. This is done by a button press sequence.

Note: Do not set harvest time shorter than the actual time it takes to release all the cubes.

To adjust Harvest Time:

1.Shut the machine off by holding the On/Off button in until it shuts off (Ice Making light off).

2.Press and hold the On button again for 5 seconds, then release (Ice Making light will switch off).

3.View the lights. Compare to the table below.

Harvest Time Table

 

On/Off

Water

Clean

Default

off

off

off

Add 10 seconds

on

off

off

Add 20 seconds

off

on

off

Add 30 seconds

off

off

on

Add 40 seconds

on

on

on

- 10 seconds

flash

off

off

- 20 seconds

off

flash

off

- 30 seconds

off

off

flash

- 40 seconds

flash

flash

flash

4.Select the amount of change.

5.Push and release the Clean button until the correct light pattern is displayed.

6.Push and release the On button to select that setting.

7.Push and release On/Off to return to ice making.

June 2008

Page 14

Image 14
Contents Table of Contents IntroductionSpecifications LEG Adjustment Places Drain Flexible Tubing Cabinet LayoutAir flow Scale can shorten machine life Installation OverviewWater Quality Filters and TreatmentDoor Covering Door Panel Custom PanelDoor Panel Attachment Custom Panel Installation Notes Door swing changeInstallation Water & Drain Drain Pump Model drain installationGravity Drain Initial Start Up Installation check listElectrical Cube Size Adjustment Cube Size Change TableHarvest Time Adjustment Harvest Time TableReset time to clean indicator light Control SettingsAutomatic water purge enable / disable Use How to clean the condenser and winterize Condenser cleaningHow to remove scale from the ice making system System Information Water System Components Controller Maximum Harvest Time minutesPerformance Information Discharge Pressure Refrigeration SystemTime Thermistor Values Deg. F · Ohms Deg. F. · OhmsService Diagnosis Problem Likely Cause Probable SolutionMakes excessive noise Removal and Repair Control Panel Evaporator ThermistorController TransformerRemoval and Repair Cabinet Removal Page Refrigeration Service