Scotsman Ice SCCP50, SCCG50 service manual Control Settings, Automatic water purge enable / disable

Page 15

SCCG50 & SCCP50

Service Manual

Control Settings

Automatic water purge enable / disable

The control is set at the factory to automatically select the proper amount of water purge. If desired, that can be disabled, and a typical purge amount used.

To disable Automatic purge selection:

1.Press and hold the On/Off button until the unit shuts off. No lights should be on.

2.Press and hold the ON button for 5 seconds, then release.

3.Wait between 5 and 20 seconds, then repeat step 1. All lights will flash once.

To return to Automatic purge selection:

1.Press and hold the ON button for 5 seconds, then release.

2.Wait between 5 and 20 seconds, then repeat step 1. All lights will flash twice.

Manual Harvest - from the OFF or Standby Mode (powered but no lights are on)

1.Press and hold the Clean-Reset button for 5 seconds and release.

2.Wait between 5 and 20 seconds, then repeat step 1. All lights will flash once. The On/Off light will be on until harvest has timed out.

Reset time to clean indicator light

Press and hold the Clean-Reset button for 3 seconds.

June 2008

Page 15

Image 15
Contents Introduction Table of ContentsSpecifications Cabinet Layout LEG Adjustment Places Drain Flexible TubingAir flow Filters and Treatment Installation OverviewWater Quality Scale can shorten machine lifeDoor Panel Custom Panel Door CoveringDoor Panel Attachment Custom Panel Door swing change Installation NotesDrain Pump Model drain installation Installation Water & DrainGravity Drain Installation check list ElectricalInitial Start Up Cube Size Change Table Cube Size AdjustmentHarvest Time Table Harvest Time AdjustmentControl Settings Automatic water purge enable / disableReset time to clean indicator light Use Condenser cleaning How to clean the condenser and winterizeHow to remove scale from the ice making system System Information Water System Components Maximum Harvest Time minutes ControllerPerformance Information Refrigeration System TimeDischarge Pressure Deg. F · Ohms Deg. F. · Ohms Thermistor ValuesProblem Likely Cause Probable Solution Service DiagnosisMakes excessive noise Removal and Repair Transformer Evaporator ThermistorController Control PanelRemoval and Repair Cabinet Removal Page Refrigeration Service