Scotsman Ice SCCP50, SCCG50 service manual Performance Information

Page 23

SCCG50 & SCCP50

Service Manual

Performance Information

Freeze Cycle, Minutes

 

 

Air Temperature

 

 

100

90

80

70

60

50

 

 

 

 

100

37-38

36-37

34-35

32-33

31-32

29-30

 

90

 

36-37

35-36

33-34

31-32

30-31

28-29

 

80

 

36-35

32-33

30-31

28-29

27-28

26-27

Water

70

 

32-33

28-29

27-28

25-26

23-24

22-23

Temperature

 

60

 

27-28

25-26

24-25

22-23

20-21

19-20

 

 

 

50

 

20-21

19-20

18-19

17-18

16-17

15-16

 

40

 

18-19

17-18

16-17

15-16

15-16

15-16

 

 

 

 

 

 

 

 

Harvest Cycle, Seconds

 

 

Air Temperature

 

 

100

90

80

70

60

50

 

 

 

 

80

-100

55-60

60-70

70-80

80-90

90-100

110-115

Water

70

- 80

65-75

70-80

75-85

85-95

95-105

115-120

Temperature

50

- 70

70-80

75-85

85-95

125-135

140-150

160-170

 

 

40

- 50

100-120

115-125

130-140

150-170

180-200

210-230

 

 

 

 

 

 

 

 

Total Cycle, Minutes

 

 

Air Temperature

 

 

100

90

80

70

60

50

 

 

 

 

100

38-39

37-38

36-37

34-35

33-34

31-32

 

90

 

38-39

36-37

35-36

33-34

32-33

30-31

 

80

 

37-38

33-34

31-32

30-31

29-30

27-28

Water

70

 

33-34

29-31

28-29

26-27

25-26

24-25

Temperature

 

60

 

29-30

27-28

25-26

24-25

22-23

21-22

 

 

 

50

 

21-22

20-21

19-20

19-20

19

18-19

 

40

 

20-21

19-20

19

18-19

19

19-21

Ice per cycle: 1 lb

Water drained / cycle: Varies by harvest cycle length and purge setting. Typical amounts are @ 70/50 = 52 oz. @ 90/70 = 13 oz

Compressor amps: 2.6 - 3.2

June 2008

Page 23

Image 23
Contents Introduction Table of ContentsSpecifications Cabinet Layout LEG Adjustment Places Drain Flexible TubingAir flow Filters and Treatment Installation OverviewWater Quality Scale can shorten machine lifeDoor Panel Custom Panel Door CoveringDoor Panel Attachment Custom Panel Door swing change Installation NotesDrain Pump Model drain installation Installation Water & DrainGravity Drain Initial Start Up Installation check listElectrical Cube Size Change Table Cube Size AdjustmentHarvest Time Table Harvest Time AdjustmentReset time to clean indicator light Control SettingsAutomatic water purge enable / disable Use Condenser cleaning How to clean the condenser and winterizeHow to remove scale from the ice making system System Information Water System Components Maximum Harvest Time minutes ControllerPerformance Information Discharge Pressure Refrigeration SystemTime Deg. F · Ohms Deg. F. · Ohms Thermistor ValuesProblem Likely Cause Probable Solution Service DiagnosisMakes excessive noise Removal and Repair Transformer Evaporator ThermistorController Control PanelRemoval and Repair Cabinet Removal Page Refrigeration Service