Vulcan-Hart EG60, EG160, EG260 Regulator CHECK, ADJUSTMENT, Installation, Regulator Adjustment

Page 22

REGULATOR CHECK, ADJUSTMENT, INSTALLATION (Cont.)

2.With only two open top burners “ON”, note the manometer reading. The reading should be 3.7" Water Column (.92 kPa) for natural gas units and 10.0" Water Column (2.5 kPa) for propane gas units. If readings taken are lower, check the incoming line pressure. NOTE: The line pressure should never drop below 5.0" Water Column (1.25 kPa) for natural gas or 11.0" Water Column (2.7 kPa) for propane gas.

If line pressure is incorrect, it must be adjusted in order to properly operate the unit . If the line pressure is good, then the regulator requires adjustment (refer to procedures for regulator adjustment).

If, after the regulator adjustment has been made, the 3.7" Water Column (.92 kPa) (natural gas) or 10.0" Water Column (2.5 kPa) (propane gas) still is not being maintained, replace the regulator.

3.With the regulator now reading 3.7" Water Column (.92 kPa) (natural gas) or 10.0" Water Column (2.5 kPa) (propane gas), turn two open top burners “ON”.

4.Recheck the pressure reading. The reading should not fluctuate more than ± .10" (0.7 kPa). If reading is not within tolerance, replace the regulator.

NOTE: When the burners are “OFF”, if the pressure reading climbs to an outlet regulator pressure stated in Step 2, check the regulator vent for obstruction (Figs. 24 & 25).

Fig. 24

Fig. 25

Check also for gas leak at vent. If vent is leaking gas, replace the regulator.

REGULATOR ADJUSTMENT

TOOLS REQUIRED: Flat blade screwdriver, manometer, and 6" adjustable wrench.

NOTE: Before making a regulator adjustment, always verify that the incoming line pressure is correct. The required incoming minimum line pressure for the Restaurant Range series is 5.0" (1.25 kPa) for natural gas and 11.0" (2.7 kPa) for propane gas. If the line pressure is not correct, it must be rectified or the unit will not properly operate or achieve proper regulator adjustment. Also, the regulator must be attached to the unit in the horizontal position with the arrow pointing in the direction of the gas flow (see Fig. 7).

– 23 –

Image 22
Contents EG24, 36, 48, 60, 160 Important for Your Safety For Your SafetyGAS Restaurant Range Models Thermostat Adjustments Dedicated Technical Service HOT Line Service NotationsUnits Mounted on Casters Servicing Simple Checks and AdjustmentsAdjustments Checks2A L Oven Door J-Bolt Assembly Servicing Simple Checks and AdjustmentsOven Door Turnbuckle Pilot Flame Height Air Shutter Adjustment GAS Connections Testing the GAS Supply System GAS ConnectionsHOT TOP and Griddle TOP Burners Pilot Lighting and AdjustmentsHOT TOP and Griddle TOP Pilot Burner Adjustments Complete ShutdownOpen TOP Burner Adjustments Pilot Lighting and AdjustmentsOpen TOP Burners BROILER/GRIDDLE BROILER/GRIDDLE AdjustmentsStandard Oven Turn oven burner valve OFF Turn main gas supply OFF Oven Burner Adjustments Thermostat Adjustments Bypass AdjustmentThermostat Adjustments Temperature CalibrationThermostat Adjustments Thermostat Adjustments Regulator CHECK, ADJUSTMENT, Installation Regulator CheckRegulator CHECK, ADJUSTMENT, Installation Regulator AdjustmentRegulator Installation Standard Oven and Griddle Thermostat Replacement Standard Oven & Griddle Thermostat ReplacementStandard Oven and Griddle Thermostat Checks and Calibration Thermostat Replacement Standard Oven & GriddleStandard Oven & Griddle Oven Pilot Replacement Oven Pilot CHECK, ReplacementOven Pilot Check Standard Oven Pilot Safety Valve CHECK, Replacement Standard Oven Pilot Safety Valve CheckStandard Oven Pilot Safety Valve CHECK, Replacement Safety Valve Replacement ProceduresStandard Oven Pilot Safety Valve CHECK, Replacement Thermocouple Replacement Thermocouple CHECK, ReplacementThermocouple Check Oven Burner Nozzle and Orifice Replacement Oven Burner Nozzle and Orifice CheckOven Burner Replacement Oven Burner CHECK, ReplacementOven Burner Check TOP Section Pilot Replacement TOP Section Pilot CHECK, ReplacementPilot Adjustment Valve Replacement TOP Section Pilot CheckTOP Section Burner Valve and Nozzle Replacement TOP Section Burner Valve and Nozzle CHECK, ReplacementTOP Section Burner Valve Check

EG48, EG36, EG60, EG260, EG160 specifications

Vulcan-Hart is renowned for its commitment to producing high-quality commercial cooking equipment, and its line of electric griddles is a testament to this legacy. The Vulcan-Hart EG series, which includes the EG160, EG260, EG60, EG36, and EG48 models, is designed with efficiency, durability, and versatility in mind, making them ideal for restaurants, hotels, and catering services.

One of the standout features of the Vulcan-Hart EG series is its robust cooking surface. Each model is equipped with a polished, stainless steel griddle plate that ensures even heat distribution, promoting consistent cooking results. The griddles come in various sizes to meet different kitchen demands, with cooking areas that range from 36 inches to 60 inches wide. This variety allows operators to choose the right size for their specific needs, ensuring maximum output and efficiency.

The thermal efficiency of the EG series is further enhanced by its design. The griddles are equipped with powerful heating elements, which are recessed to provide an uninterrupted cooking surface. This not only contributes to excellent heat retention and recovery but also makes cleaning easier. Operators can enjoy reduced downtime while maintaining peak performance.

Safety and usability are also key considerations in the design of Vulcan-Hart griddles. Each unit features a temperature control system that allows for precise heat management, ensuring consistency in cooking temperatures. The griddles include adjustable legs for leveling, making them adaptable to various kitchen environments. Additionally, the high-quality construction and materials also make these griddles resistant to the rigors of a busy commercial kitchen.

In terms of technologies, Vulcan-Hart has integrated innovative designs into the EG series, such as built-in grease troughs and drains that facilitate easy cleanup. The sleek exterior is not just for aesthetics; it’s designed for easy maintenance and longevity in demanding kitchen settings.

Overall, the Vulcan-Hart EG series of electric griddles encapsulates a blend of performance, durability, and ease of use, making them an invaluable asset in any commercial kitchen. Whether you're cooking pancakes, burgers, or stir-fry, the EG160, EG260, EG60, EG36, and EG48 models are engineered to deliver outstanding results while streamlining kitchen operations.