TEMPERATURE PROBE
Disconnect the electrical power to the machine and follow lockout / tagout procedures.
1.Remove the
2.Disconnect probe leads from the solid state temperature controller on the SG4D/SG6D or the computer controller on the SG4C/SG6C.
3.Remove the racks and right rack support.
4.Remove the upper and lower door seals.
5.Loosen the three screws securing the right side air scoop to the rear heat exchanger. Rotate the air scoop off of the heat exchanger tube into the oven cavity.
6.Remove the screws that secure the perforated side panel and lift out.
7. Remove the probe from the bracket(s).
SG4C/SG6C Temperature Probe Shown
8.Push the probe through the oven wall and into the control panel area.
9.Reverse the procedure to install the new probe.
10.Calibration:
A.SG4D/SG6D: Adjust the temperature controller as outlined under Solid State Control Calibration.
B.SG4C/SG6C: Adjust the computer controller as outlined under Computer Controller and/or Computer Controller Calibration in Service Procedures and Adjustments.