COMPUTER CONTROLLER
(SG4C/SG6C)
Operation
Refer to the Installation & Operation Manual for specific operating instructions.
Setup Mode
Use the setup mode to verify that the control is configured to the factory settings which result in the proper operation of the oven. If the CAL1 parameter is other than zero, see Computer Control Calibration (SG4C/SG6C).
CAUTION: Changing the C_F, InP1, rL1 and rH1 parameters will default all menus.
1.Use this key sequence to access the setup mode: UP arrow, Rack 1, Temperature, Temperature, DOWN arrow, Rack 1.
1 1
2.Once in the setup mode the display will alternate between the parameter and programmed data.
A.To change data to the factory setting, use the arrow keys.
B.To select the next parameter, press the Rack 1 key.
C.After the last parameter and data are viewed, press the Rack 1 key to exit the setup mode and return to operations mode. The current set point temperature will be displayed.
D.If there are no key activations after 1 minute, the control will return to operation mode.
3.Listed are the parameters and data in the setup mode.
| ALTERNATING ON DISPLAY | ||
MENU |
|
| |
PARAMETER | DATA | ||
| |||
|
|
| |
Celsius_Fahrenheit | C_F | F | |
|
|
| |
Guard Band | gb | 4000 | |
|
|
| |
Temperature | tcnP | OFF | |
Compenstaion | |||
|
| ||
|
|
| |
Input Type 1 | InP1 | J | |
|
|
| |
Range Low 1 | rL1 | 75 | |
|
|
| |
Range High 1 | rH1 | 500 | |
|
|
| |
Hysteresis | HYS1 | 3 | |
|
|
| |
Calibration Offset | CAL1 | 0 | |
|
|
| |
Exit setup mode | Set point temperature is | ||
and return to | displayed or if calling for heat, | ||
operation mode. | dashes | ||
|
|
|
Probe Test
If the oven is not heating or displaying the proper temperature, the temperature probe may be malfunctioning. Determine if the probe is good or causing the operational problem.
1.Temporarily disconnect the existing lead wires from the computer control and connect them to a good
2.Turn the power switch to ON and set the temperature controller to 350°F.
A. If the oven reaches the set temperature and cycles with the temporary thermocouple, then the existing probe is malfunctioning.
3.Replace the temperature probe with the correct part and check for proper operation.
– 23 –