IGNITION CONTROL MODULE
Disconnect the electrical power to the machine and follow lockout / tagout procedures.
1.Remove the right side cover as outlined under Covers and Panels.
2.Loosen the screws securing the mounting bracket to the component panel and remove the bracket.
3.Disconnect the lead wires and igniter cables from the ignition module board.
4.Remove the ignition module board from the mounting bracket.
5.Reverse the procedure to install the replacement ignition module board.
6.Check for proper operation.
SPARK IGNITER AND FLAME SENSE
Disconnect the electrical power to the machine and follow lockout / tagout procedures.
Shut off the gas before servicing the oven.
1.Remove the two gas burners as outlined under Gas Burners.
2.Remove the screws securing the igniter and flame sense to each burner. Remove the assembly.
3.The spark gap is 1/8" from the inside of the spark rod to the inside to the ground rod. The ground rod (the end of the spark) is 1/8" above the burner. If the gap is not correct or poor sparking is occurring, then adjust accordingly.
4.Reverse the procedure to install the assembly and check for proper operation.
– 13 –