GENERAL
INTRODUCTION
Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific. All models are equipped with a
Models SG4D and SG6D are equipped with solid
Models SG6D and SG6C have a 4" deeper cavity than models SG4D and SG4C.
INSTALLATION
Generally, installations are made by the dealer or contracted by the dealer or owner. Detailed installation instructions are included in the Installation & Operation Manual which is sent with each unit.
Gas Data
Model | Input BTU/hr | Manifold Pressure | |||
SG4D, | Natural | LP Gas | Natural | LP Gas | |
SG4C, |
|
|
|
| |
SG6D, | 60,000 | 60,000 | 3.5" W.C. | 10" W.C. | |
SG6C | (0.9 kPa) | (2.2 kPa) | |||
|
| ||||
|
|
|
|
|
OPERATION
Detailed operation instructions are included with each oven.
CLEANING
Detailed cleaning procedures are included in the Installation & Operation Manual for the appropriate model.
LUBRICATION
Motor bearings are sealed and prelubricated.
SPECIFICATIONS
Electrical Data
Model | Volts | Hertz | Phase | Amps | |
|
|
|
|
| |
SG4D | 120 | 60 | 1 | 7.5 | |
SG4C |
|
|
|
| |
208 | 60 | 1 | 3.6 | ||
SG6D | |||||
|
|
|
| ||
SG6C | 240 | 60 | 1 | 3.75 | |
|
|
|
|
|
TOOLS
Standard
•Hand tools (standard set).
•VOM with AC current tester (any quality VOM with a sensitivity of at least 20,000 ohms per volt can be used).
•Gear puller to remove blower.
Special
•Temperature tester (thermocouple type).
•Manometer
– 5 –