DOOR ADJUSTMENT
Disconnect the electrical power to the machine and follow lockout / tagout procedures.
1.Check the doors to make sure they have an equal gap between them and that the vertical edge of the door is parallel to the vertical door seal. If the doors are not positioned in this manner, adjust the doors as described.
EQUAL GAP
EQUAL GAP |
EQUAL GAP |
DOOR STRIKE ADJUSTMENT
(INDEPENDENT DOORS)
NOTE: For units with serial number starting with 48 made after 8/12/07 and serial number starting with 54 made after 8/26/07.
Disconnect the electrical power to the machine and follow lockout / tagout procedures.
1.Remove the top front cover as outlined under COVERS AND PANELS in REMOVAL AND REPLACEMENT OF PARTS.
2.Open the doors and inspect the door strike for proper shape.
A.Replace if bent. Do not bend strike plate.
B.If adjustment is necessary, loosen fasteners, close doors and insure contact between the door inner surface and upper horizontal seal. Slide door strike plate until contact with roll latch is made. Tighten strike plate fasteners.
2.Remove the top front cover.
3.Loosen the screws that secure the upper door bearings and related hardware, just enough to allow door movement.
UPPER | LOOSEN |
BEARING | SCREWS |
| DOOR |
| SHAFT |
|
4.Move the door until proper alignment is achieved, then tighten the screws on the upper door bearing hardware.
5.Repeat steps 3 and 4 on the opposite door if necessary.
6.If one door is higher than the other, add or remove shims under hinge pin as needed.
3.Open and close the doors several times while observing the roller latch and strike plate operation.
A. Replace roller latch if malfunctioning as outlined under ROLLER LATCH ASSEMBLY (INDEPENDENT DOORS) and adjust as outlined in this procedure.
4.Each oven door should be open with a force of 8 to 25 pounds when pulled at the handle. The adjustments must allow the doors to remain closed during normal operation and allow opening without exertion by the user.
– 28 –