GAS ORIFICE
Disconnect the electrical power to the machine and follow lockout / tagout procedures.
Shut off the gas before servicing the oven.
1.Remove the lower front cover as outlined under Covers and Panels.
2.Remove the bolts securing the gas manifold and place manifold aside.
3.There are two gas orifices on the manifold. Remove each orifice and replace with the correct orifice for the given altitude as needed.
4.Reverse the procedure to install manifold and check for proper operation.
GAS SOLENOID VALVE
3.Disconnect compression fittings from the valve.
4.Loosen the bolts securing the valve and bracket assembly, then remove the screws securing the valve to the bracket.
Disconnect the electrical power to the machine and follow lockout / tagout procedures.
Shut off the gas before servicing the oven.
1.Remove the control panel and the right side panel as outlined under Covers and Panels.
2.Disconnect the lead wires.
5.Reverse the procedure to install the replacement gas valve.
All gas joints disturbed during servicing must be checked for leaks. Check with soap and water solution (bubbles). Do not use an open flame.
6.Verify gas pressure as outlined under the Gas Pressure Adjustment in Service Procedures and Adjustments. Check for proper operation.
– 12 –