Operation Function
9-15) Load Operation Check Function
1)In the normal operation, press Power Freeze(Quick Ice) and Power Cool buttons simultaneously for 6 second, then the display panel will blink for 2 seconds.
2)Press Fridge Temp. button ⓐ to get into this check mode with an audible tone.
3)Each illuminating LED segment stands for the component which has an ouput signal from the control board.
4)This mode will terminate automatically after 30 seconds.
Table of Load Mode Check List
NO | Contents | |
|
|
|
① | ||
|
|
|
② | ||
③ |
| |
④ | Start mode | |
⑤ | Overload mode | |
⑥ | ||
⑦ | Exhibition mode | |
⑧ | COMP | |
⑨ | ||
⑩ | ||
⑪ | ||
⑫ | ||
⑬ | ||
⑭ | ||
⑮ | Damper | |
- | Normal condition |
※For the
※The
※④⑤ and ⑥ only explain the system operation status according to the ambient condition
9-16) Restoration Function for Power Outage
1)When the freezer temperature is lower than 41℉, all functions on the display panel will be restored.
2)When the freezer temperature is higher than 41℉, all functions will be initialized.
9-17) Set Point Shift Function
●Press Freezer Temp. and Power Cool buttons simultaneously for 12 seconds to get into this mode.
●In this mode, only the display LEDs for temperature will be ON.
33