Circuit Descriptions
Note) To prevent the malfunction from a high humidity, a DC 12V, 1 watt heater is mounted and activated continuously.
10-8) Fan Motor (BLDC) Drive Circuit
1) Motor drive circuit
1-2) Voltages between high-speed and low-speed
|
| Voltage of motor |
| Remark | |
|
|
|
|
|
|
| Measure b | Measure C |
| Measure | In the normal operation, MICOM No. 40, 41 and 42 applies a constant frequency; and |
|
|
|
|
| |
High | 11.1V | 10V |
| 10V | MICOM defects the signal to check the failure of motor. |
|
|
|
|
| (frequency(Hz)×12 = motor rpm) |
Low | 10V | 10V |
| 8.3V | |
|
|
Note) Under the conditions, the fans will be operated in 2 options, such as High and Low mode. Generally, it is operated in the High mode during a day time and in the Low mode at night.