Diagnostics
Preliminary check
1)Check if the solenoid is unconditionally operated for 0.3 sec, independent of the Open/Close condition of cover
2)Check if the connector in upper hinge section is
|
|
|
|
|
|
|
|
| Start |
|
|
|
|
|
|
| ||||
|
|
|
| YES |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| Is the S/N(solenoid) for |
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| 0.3 sec operated after 5 seconds |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| from power ON? |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
The S/N control PCB assembly and |
|
|
|
|
|
|
|
|
| NO |
|
|
|
|
|
|
| |||
wire system have no trouble. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Is MICOM No. 27 on |
| YES |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| NO |
|
|
|
|
| PCB maintaining High for 0.3 sec at the first |
|
|
|
|
|
|
|
| ||||
Press Ice lever and keep it open. |
|
|
|
|
| power |
| ON? |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| NO |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| MICOM control port is normal. |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| YES | NO |
|
|
|
|
| Exchange the main PCB assembly. |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
Is the cover closed of |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| NO |
| Does |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
S/N after about |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
7∼10 | seconds? |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| of TR Q701 turn ON for 0.3 sec? |
| |
| YES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| After replace TR Q701 and check SSR71 then |
|
|
|
|
| YES |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| exchange the failed components or replace the |
|
|
|
|
|
| |||||
All the control system of cover ice- |
|
|
|
|
|
|
| PCB assembly. |
|
|
|
| TR701 and SSR71 are normal |
| ||||||
route has no trouble. |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Check the stop lever and support |
| ||||
|
|
|
|
| |||||
|
|
|
|
| |||||
With the ice S/W ON |
| YES | |||||||
and ICE S/W on, |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| NO |
|
|
| Subject to the ice | |||
|
|
|
|
|
|
| S/W ON, do CN31 No. 2 and MICOM No. 45 | ||
|
|
|
|
|
| ||||
|
|
|
|
|
|
| get impressed 0V? | ||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||
Check the ICE S/W, and troubleshoot |
|
|
|
| YES | ||||
the wire connection system. |
|
|
|
|
|
| |||
|
|
|
|
|
|
- Main PCB and the sensing section of
- Check the operation of SSR71 and Q701.
56