Diagnostics
11-4) If there is a trouble with self-diagnosis
-Error of sensor can be seen on the front display of refrigerator. If power is impressed to refrigerator first, an failure of sensor is found. The refrigerator will stop working and display(blink) the region of
-Even if sensor has failure during the operation, the refrigerator will not stop working but can run the normal cooling operation because of being operated in the Emergency Operation mode. Therefore you’ re requested to use how to check
1) If the ambient sensor has trouble
Start
See Ref. 4 (descriptions of circuit operation, and how to check temperature sensor in the manual.)
Was the Main
–PCB connector(CN31) inserted correctly?
YES
Is the ambient temperature
sensor normal?
YES
Is the input of voltage to
MICOM pin No. 63 normal?
YES
No trouble with PCB and temperature sensor.
Recheck the contact failure of connector.
NO
NO
NO
A bad contact or connector missing?
Exchange the temperature sensor.
Check the iced solder and
short of
2) If the temperature sensor of F and R room has trouble
See Ref.4 (descriptions of circuit operation, and how to check temperature sensor in the manual.)
For sensor resistance per temperature, make use of the resistance values from Ref. 4 and 5.
Start
Is the unit of | NO | ||
Fridge’s temperature |
| ||
sensor normal? |
| ||
| YES |
| |
|
| ||
Was the Main – PCB | NO | ||
connector(CN30) inserted |
| ||
correctly? |
| ||
| YES |
| |
|
| ||
Is the sequence of | NO | ||
insertion of connector(CN30) wire identical to |
| ||
the circuit diagram? |
| ||
| YES |
| |
|
| NO | |
Is the input voltage to | |||
|
MICOM pin No. 59 normal?
YES
No trouble with PCB and temperature sensor.
Recheck the connector for an error of contact.
Exchange the temperature sensor.
Troubleshoot a bad contact or missing of
connector.
Modify the wrong configuration of connector wire
Check if the iced solder of main PCB is
short.
49